MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d3ay01408h

Медицинская библиотека · Analytical methods : advancing methods and applications · 2023

Development of a cell-free toehold switch for hepatitis A virus type I on-site detection.

Kang Xiaodan, Zhao Chen, Chen Shuting, Zhang Xi, Xue Bin, Li Chenyu, Wang Shang, Yang Xiaobo, Xia Zhiqiang, Xu Yongchun, Huang Yongliang, Qiu Zhigang, Li Chao, Wang Jingfeng, Pang Jian, Shen Zhiqiang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Picornavirus hepatitis A virus (HAV) is a common cause of hepatitis worldwide. It is spread primarily through contaminated food and water or person-to-person contact. HAV I has been identified as the most common type of human HAV infection. Here, we have developed a cell-free toehold switch sensor for HAV I detection. We screened 10 suitable toehold switch sequences using NUPACK software, and the VP1 gene was used as the target gene. The optimal toehold switch sequence was selected by in vivo expression. The best toehold switch concentration was further found to be 20 nM in a cell-free system. 5 nM trigger RNA activated the toehold switch to generate visible green fluorescence. The minimum detection concentration decreased to 1 pM once combined with NASBA. HAV I trigger RNA could be detected accurately with excellent specificity. In addition, the cell-free toehold switch sensor was verified in HAV I entities. The successful construction of the cell-free toehold switch sensor provided a convenient, rapid, and accurate method for HAV I on-site detection, especially in developing countries, without the involvement of expensive facilities and additional professional operators.

Для цитирования: Kang Xiaodan, Zhao Chen, Chen Shuting, Zhang Xi, Xue Bin, Li Chenyu, Wang Shang, Yang Xiaobo, Xia Zhiqiang, Xu Yongchun, Huang Yongliang, Qiu Zhigang, Li Chao, Wang Jingfeng, Pang Jian, Shen Zhiqiang. Development of a cell-free toehold switch for hepatitis A virus type I on-site detection.. Analytical methods : advancing methods and applications. 2023. DOI: 10.1039/d3ay01408h.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.