Changes in Peripheral Refractive Profile after Orthokeratology for Different Degrees of Myopia.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
González-Méijome José Manuel, Faria-Ribeiro Miguel A, Lopes-Ferreira Daniela P, Fernandes Paulo, Carracedo Gonzalo, Queiros Antonio
Аннотация
PURPOSE: The purpose of this study was to evaluate the effect of orthokeratology for different degrees of myopia correction in the relative location of tangential (F(T)) and sagittal (F(S)) power errors across the central 70° of the visual field in the horizontal meridian.
METHODS: Thirty-four right eyes of 34 patients with a mean age of 25.2 ± 6.4 years were fitted with Paragon CRT (Mesa, AZ) rigid gas permeable contact lenses to treat myopia (-2.15 ± 1.26D, range: -0.88 to -5.25D). Axial and peripheral refraction were measured along the central 70° of the horizontal visual field with the Grand Seiko WAM5500 open-field auto-refractor. Spherical equivalent (M), as well as tangential (FT) and sagittal power errors (FS) were obtained. Analysis was stratified in three groups according to baseline spherical equivalent: Group 1 [M(Baseline) = -0.88 to -1.50D; n = 11], Group 2 [M(Baseline) = -1.51 to -2.49D; n = 11], and Group 3 [M(Baseline) = -2.50 to -5.25D; n = 12].
RESULTS: Spherical equivalent was significantly more myopic after treatment beyond the central 40° of the visual field (p < 0.001). FT became significantly more myopic for all groups in the nasal and temporal retina with 25° (p ≤ 0.017), 30° (p ≤ 0.007) and 35° (p ≤ 0.004) of eye rotation. Myopic change in FS was less consistent, achieving only statistical significance for all groups at 35° in the nasal and temporal retina (p ≤ 0.045).
CONCLUSIONS: Orthokeratology changes significantly FT in the myopic direction beyond the central 40° of the visual field for all degrees of myopia. Changes induced by orthokeratology in relative peripheral M, FT and FS with 35° of eye rotation were significantly correlated with axial myopia at baseline.
METHODS: Thirty-four right eyes of 34 patients with a mean age of 25.2 ± 6.4 years were fitted with Paragon CRT (Mesa, AZ) rigid gas permeable contact lenses to treat myopia (-2.15 ± 1.26D, range: -0.88 to -5.25D). Axial and peripheral refraction were measured along the central 70° of the horizontal visual field with the Grand Seiko WAM5500 open-field auto-refractor. Spherical equivalent (M), as well as tangential (FT) and sagittal power errors (FS) were obtained. Analysis was stratified in three groups according to baseline spherical equivalent: Group 1 [M(Baseline) = -0.88 to -1.50D; n = 11], Group 2 [M(Baseline) = -1.51 to -2.49D; n = 11], and Group 3 [M(Baseline) = -2.50 to -5.25D; n = 12].
RESULTS: Spherical equivalent was significantly more myopic after treatment beyond the central 40° of the visual field (p < 0.001). FT became significantly more myopic for all groups in the nasal and temporal retina with 25° (p ≤ 0.017), 30° (p ≤ 0.007) and 35° (p ≤ 0.004) of eye rotation. Myopic change in FS was less consistent, achieving only statistical significance for all groups at 35° in the nasal and temporal retina (p ≤ 0.045).
CONCLUSIONS: Orthokeratology changes significantly FT in the myopic direction beyond the central 40° of the visual field for all degrees of myopia. Changes induced by orthokeratology in relative peripheral M, FT and FS with 35° of eye rotation were significantly correlated with axial myopia at baseline.