MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2011.07.020

Медицинская библиотека · Journal of shoulder and elbow surgery · 2011

Clavicle hook plate fixation for displaced lateral-third clavicle fractures (Neer type II): a functional outcome study.

Good Daniel W, Lui Darren F, Leonard Michael, Morris Seamus, McElwain John P

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Controversy exists with the use of the acromioclavicular hook plate for the treatment of lateral-third clavicle fractures (Neer type II). This is thought to stem from problems associated with the hook plate causing impingement symptoms, which can cause long-term limitation of movement and pain. Our aim was to evaluate the functional outcomes of patients with lateral-third clavicle fractures treated with the hook plate.

METHODS

We prospectively reviewed all patients who underwent surgery from July 2005 to August 2009 using our prospectively recorded electronic patient information database. All patients were assessed in the clinic to determine both Oxford and Constant shoulder scores.

RESULTS

We identified 36 patients who underwent surgery with the hook plate, 26 men and 10 women. The mean age was 36.2 years (range, 22-60 years). Of the patients, 46% were smokers. The median length of hospital stay was 2 days (interquartile range [IQR], 1-3). The median follow-up was 28 months (IQR, 23-37). The median time from date of injury to surgery was 7 days (IQR, 4-76). The mean time to union was 3 months (IQR, 2-4), and the union rate was 95%. In total, 92% of plates were removed. The median time to removal was 4.5 months (IQR, 3-8.75). There were no complications. Two patients presented months later after falls with fractures around the medial end of the hook plate.

CONCLUSION

Hook plates are an effective form of treatment for lateral third clavicle fractures. The best outcomes occur with plate removal before 6 months postoperatively, provided that the fracture has healed.

Для цитирования: Good Daniel W, Lui Darren F, Leonard Michael, Morris Seamus, McElwain John P. Clavicle hook plate fixation for displaced lateral-third clavicle fractures (Neer type II): a functional outcome study.. Journal of shoulder and elbow surgery. 2011. DOI: 10.1016/j.jse.2011.07.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.