Cemented Thompson versus cemented bipolar prostheses for femoral neck fractures.

Bauer Stefan, Isenegger Patrick, Gautschi Oliver P, Ho Kwok M, Yates Piers J, Zellweger Rene

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare early functional outcomes, complications, and mortality in elderly patients treated with the less costly, cemented Thompson prosthesis or the cemented bipolar prosthesis in order to identify factors affecting outcomes.

METHODS

Records of 303 patients with femoral neck fractures treated with the cemented Thompson monoblock prosthesis (n=206) or the cemented bipolar prosthesis (n=97) were reviewed. The choice of prosthesis was solely determined by surgeon's preference. Data relating to patient demographics, clinical and residential status, mobility, mental function, mortality, and complications during hospitalisation and rehabilitation were collected.

RESULTS

After adjusting for confounding variables, independent postoperative indoor mobility was associated with preoperative indoor mobility (p=0.002) and mental function (p=0.001), whereas postoperative outdoor mobility was associated with preoperative outdoor mobility (p=0.003), daily living activity (p=0.02), and mental function (p=0.02). Mortality within 6 months was only associated with poor mental function (p=0.009). At 6-month follow-up, there was no significant difference between the 2 types of prosthesis in terms of functional outcomes, mortality and complication rates.

CONCLUSION

In elderly patients with limited mobility, treatment with the bipolar prosthesis was not associated with better short-term outcomes than those receiving the Thompson prosthesis.

Для цитирования: Bauer Stefan, Isenegger Patrick, Gautschi Oliver P, Ho Kwok M, Yates Piers J, Zellweger Rene. Cemented Thompson versus cemented bipolar prostheses for femoral neck fractures.. Journal of orthopaedic surgery (Hong Kong). 2010. DOI: 10.1177/230949901001800207.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.