Медицинская библиотека · The journal of applied laboratory medicine · 2025

Secretoneurin Concentrations Measured with a High-Throughput Assay and Clinical Outcomes in Patients Hospitalized with Acute Dyspnea: Data from the Akershus Cardiac Examination 2 Study.

Røsjø Helge, Rugolo Ilde, Gjørven Angelica, Faaren Arne L, Frantzen Frank, Christensen Geir, Høiseth Arne Didrik, Ottesen Anett H, Bhatnagar Rahul, Lyngbakken Magnus N, Omland Torbjørn

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

High-throughput assays are required for novel biomarkers to have clinical potential. Secretoneurin (SN) is a candidate biomarker, and the performance of a new high-throughput SN assay is not known.

METHODS

We measured SN concentrations with a prototype chemiluminescent immunoassay (CLIA) in 299 patients hospitalized with acute dyspnea. We compared the results with a CE-marked SN enzyme linked immunosorbent assay (ELISA). We adjudicated the cause of dyspnea as heart failure (HF) or non-HF, and we obtained information on all-cause mortality during follow-up.

RESULTS

SN concentrations measured with CLIA and ELISA were closely correlated: rho = 0.81, P < 0.001. SN CLIA concentrations were higher in HF patients (n = 129) compared to patients with non-HF-related dyspnea (n = 170): median 51 (quartile 1-3 40-69) vs 41 (32-54) pmol/L, P < 0.001. The area under the curve (AUC) of SN CLIA to diagnose HF was 0.64 (95% CI, 0.58-0.71) and the AUC of N-terminal pro-B-type natriuretic peptide (NT-proBNP) was 0.85 (0.81-0.89). During median 818 days follow-up, 110 patients died (37%). There was a nonlinear association between SN CLIA concentrations and mortality with optimal cutpoint 53 pmol/L. SN CLIA concentrations >53 pmol/L were associated with mortality after adjusting for clinical variables and NT-proBNP and cardiac troponin T concentrations: hazard ratio 1.7 (95% CI, 1.1-2.7), AUC 0.67 (0.61-0.74). We found similar results for SN ELISA for diagnosis and prognosis with AUC 0.63 (0.57-0.70) for the prediction of mortality.

CONCLUSION

The high-throughput SN CLIA correlates with the SN ELISA and provides independent prognostic information over established biomarkers in patients with acute dyspnea.

Для цитирования: Røsjø Helge, Rugolo Ilde, Gjørven Angelica, Faaren Arne L, Frantzen Frank, Christensen Geir, Høiseth Arne Didrik, Ottesen Anett H, Bhatnagar Rahul, Lyngbakken Magnus N, Omland Torbjørn. Secretoneurin Concentrations Measured with a High-Throughput Assay and Clinical Outcomes in Patients Hospitalized with Acute Dyspnea: Data from the Akershus Cardiac Examination 2 Study.. The journal of applied laboratory medicine. 2025. DOI: 10.1093/jalm/jfaf011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.