Relative accuracy of serum, whole blood, and oral fluid HIV tests among Seattle men who have sex with men.

Stekler Joanne D, O'Neal Joshua D, Lane Aric, Swanson Fred, Maenza Janine, Stevens Claire E, Coombs Robert W, Dragavon Joan A, Swenson Paul D, Golden Matthew R, Branson Bernard M

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Point-of-care (POC) rapid HIV tests have sensitivity during the "window period" comparable only to earliest generation EIAs. To date, it is unclear whether any POC test performs significantly better than others.

OBJECTIVE

Compare abilities of POC tests to detect early infection in real time.

STUDY

DESIGN

Men who have sex with men (MSM) were recruited into a prospective, cross-sectional study at two HIV testing sites and a research clinic. Procedures compared four POC tests: one performed on oral fluids and three on fingerstick whole blood specimens. Specimens from participants with negative POC results were tested by EIA and pooled nucleic acid amplification testing (NAAT). McNemar's exact tests compared numbers of HIV-infected participants detected.

RESULTS

Between February 2010 and May 2013, 104 men tested HIV-positive during 2479 visits. Eighty-two participants had concordant reactive POC results, 3 participants had concordant non-reactive POC tests but reactive EIAs, and 8 participants had acute infection. Of 12 participants with discordant POC results, OraQuick ADVANCE Rapid HIV-1/2 Antibody Test performed on oral fluids identified fewer infections than OraQuick performed on fingerstick (p = .005), Uni-Gold Recombigen HIV test (p = .01), and determine HIV-1/2 Ag/Ab combo (p = .005).

CONCLUSIONS

These data confirm that oral fluid POC testing detects fewer infections than other methods and is best reserved for circumstances precluding fingerstick or venipuncture. Regardless of specimen type, POC tests failed to identify many HIV-infected MSM in Seattle. In populations with high HIV incidence, the currently approved POC antibody tests are inadequate unless supplemented with p24 antigen tests or NAAT.

Для цитирования: Stekler Joanne D, O'Neal Joshua D, Lane Aric, Swanson Fred, Maenza Janine, Stevens Claire E, Coombs Robert W, Dragavon Joan A, Swenson Paul D, Golden Matthew R, Branson Bernard M. Relative accuracy of serum, whole blood, and oral fluid HIV tests among Seattle men who have sex with men.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2013. DOI: 10.1016/j.jcv.2013.09.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.