MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2001-16397

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2001

[Comparison of iodinated and barium-containing contrast media of different viscosity in the detection of pharyngeal perforation].

Keberle M, Wittenberg G, Trusen A, Baumgartner W, Hahn D

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this.

METHODS

Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration.

RESULTS

In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous than the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally.

CONCLUSIONS

Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose.

Для цитирования: Keberle M, Wittenberg G, Trusen A, Baumgartner W, Hahn D. [Comparison of iodinated and barium-containing contrast media of different viscosity in the detection of pharyngeal perforation].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2001. DOI: 10.1055/s-2001-16397.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.