INTRODUCTION
Evaluation of anterior segment parameters is crucial in ophthalmic procedures such as intraocular surgeries and contact lens fitting. However, the use of tropicamide in diabetic patients presents challenges due to its potential impact on biometric measurements. This study aims to investigate and compare the effects of 0.5% and 1% tropicamide on anterior segment parameters in diabetic patients.
METHODS
This double-masked randomized clinical trial enrolled 98 patients with diabetes mellitus. Participants were randomly assigned to receive either 0.5% or 1% tropicamide. Anterior segment parameters were measured using Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) before and 30 minutes after tropicamide administration. Parameters included anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), keratometry, central corneal thickness (CCT), white-to-white distance (WTW), and pupillary diameter (PD).
RESULTS
Both concentrations of 0.5% and 1% tropicamide induced significant changes in anterior segment parameters. There was a notable increase in PD (2.99 ± 0.62, 3.11 ± 0.55, respectively, both P-values < 0.001), ACD (both 0.10 ± 0.05, both P-values < 0.001), ACV (16.69 ± 9.56, 17.51 ± 9.26, respectively, both P-values < 0.001), and WTW (0.06 ± 0.14, 0.03 ± 0.30, respectively, both P-values < 0.001), along with a decrease in ACA (-3.50 ± 10.65, -3.30 ± 6.87, P-value < 0.001 and P-value=0.001, respectively), and CCT (-6.10 ± 8.06, -6.39 ± 9.97, respectively, both P-values < 0.001) post-dilation. However, no significant changes were observed in keratometry (front Km (-0.03 ± 0.19, -0.04 ± 0.21, respectively), back Km (0.01 ± 0.05, 0.004 ± 0.05, respectively), P-values> 0.05).
CONCLUSION
Both concentrations of tropicamide exhibited comparable effects on anterior segment parameters in diabetic patients. These post-dilation changes should be considered for accurate intraocular lens power calculation and decision-making for cataract, phakic intraocular lens, and refractive surgeries.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.