MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11206721241253633

Медицинская библиотека · European journal of ophthalmology · 2024

3D Heads-up digital filters for cataract surgery and corneal transplantation.

Mosca Luigi, Scartozzi Luca, De Filippis Alessandro, Guccione Laura, Fasciani Romina, Rizzo Stanislao

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the advantages of Ngenuity 3D digital filters for enhancing visualization during cataract and corneal transplant surgery.

METHODS

All surgeries were performed by the same experienced surgeon (L.M.) using the Ngenuity 3D heads-up visualization system connected to a microscope. Images were simultaneously captured with and without the filter in each of the following phases: endothelial evaluation, capsulorhexis, capsule rupture, vitreous leak, cortex removal, visco removal, corneal suture, descemetorhexis, DMEK graft preparation and insertion.

RESULTS

In cataract surgery, green and monochrome filters facilitate capsulorhexis in difficult situations by highlighting the anterior capsule and can improve visualization of a posterior capsular tear. The enhanced contrast of the monochrome filter is also useful for cortex and viscoelastic removal. In corneal surgery, the green filter highlights the rim of the DMEK graft during tissue preparation, the yellow filter enhances the contrast of the stained DMEK graft in the anterior chamber, the monochrome filter simplifies descemetorhexis by improving visualization of the Descemet/endothelial layer and allows a better view in red saturated images while performing sutures.

CONCLUSIONS

Ngenuity digital filters have the potential to enhance tissue visualization during cataract and corneal surgeries, especially in poor visibility conditions.

Для цитирования: Mosca Luigi, Scartozzi Luca, De Filippis Alessandro, Guccione Laura, Fasciani Romina, Rizzo Stanislao. 3D Heads-up digital filters for cataract surgery and corneal transplantation.. European journal of ophthalmology. 2024. DOI: 10.1177/11206721241253633.