Accuracy of new intraocular lens power calculation formula for short and long eyes using segmental refractive indices.

Kato Yukihito, Ayaki Masahiko, Tamaoki Akeno, Tanaka Yoshiki, Ichikawa Kei, Ichikawa Kazuo

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the accuracy of a new intraocular lens power calculation formula using segmental refractive index-based axial length (AL).

SETTING

Chukyo Eye Clinic, Nagoya, Japan.

DESIGN

Retrospective observational study.

METHODS

This study included patients undergoing preoperative examination for cataract surgery with the new Barrett True AL (BTAL) and Emmetropia Verifying Optical (EVO) formulas using segmental refractive index, and conventional Barrett Universal II (BU II) formula using equivalent refractive index. The predicted refractive error of each formula was compared with the postoperative subjective spherical equivalent.

RESULTS

The mean prediction error (MPE) in the short AL group (≤22 mm; 44 eyes) was 0.32 ± 0.40 diopter (D) for BU II, 0.22 ± 0.37 D for BTAL, and 0.10 ± 0.37 D for EVO ( P < .0001). MPE in the long AL group (≥26 mm; 92 eyes) was 0.01 ± 0.32 D for BU II, 0.04 ± 0.32 D for BTAL, and 0.09 ± 0.32 D for EVO ( P < .0001). In patients with an AL ≥ 28 mm, BU II showed a myopic trend in 57.1% of cases, while BTAL and EVO showed a hyperopic trend in 71.4%. The MPE for patients with an AL ≥ 28 mm was -0.16 ± 0.34 D for BU II, 0.18 ± 0.33 D for BTAL, and 0.16 ± 0.32 D for EVO ( P < .0001).

CONCLUSIONS

The new EVO and BTAL formulas showed higher accuracy than BU II in short eyes, whereas there was no difference in long eyes.

Для цитирования: Kato Yukihito, Ayaki Masahiko, Tamaoki Akeno, Tanaka Yoshiki, Ichikawa Kei, Ichikawa Kazuo. Accuracy of new intraocular lens power calculation formula for short and long eyes using segmental refractive indices.. Journal of cataract and refractive surgery. 2024. DOI: 10.1097/j.jcrs.0000000000001466.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.