MedElevator Войти в исследования
← Поиск публикаций

DOI 10.22336/rjo.2025.59

Медицинская библиотека · Romanian journal of ophthalmology · 2025

OCT-Based Analysis of Post-Lens Tear Film Stability in Silicone Hydrogel Contact Lenses.

Arslan Neşe, Kakil Şule Barman

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to evaluate the stability of post-lens tear film (PoLTF) and pre-lens tear film (PLTF) in three different silicone hydrogel contact lenses (CLs) using optical coherence tomography (OCT) and multifunctional topography.

MATERIALS AND

METHODS

A total of 158 participants were assigned to three groups based on the CL material: Group 1 (Lotrafilcon B), Group 2 (Senofilcon A), and Group 3 (Samfilcon A). Non-invasive average break-up time (NIAvgBUT) of the PLTF was measured after a few hours of lens wear during the first visit and after 2-4 weeks of continued use in the second visit. PoLTF thickness was assessed in five corneal quadrants using OCT, measured both indirectly and manually.

RESULTS

The mean participant age was 21.9±5.0 years. The NIAvgBUT of the PLTF was significantly higher at the first visit than at the second visit (9.5±2.9 s vs. 8.3±2.1 s, p=0.0001). Similarly, the PoLTF thickness in the central corneal area showed a significant reduction after 2-4 weeks of lens wear (p=0.001).

DISCUSSION: Our results emphasize the clinical importance of monitoring both pre-lens and post-lens tear film parameters during routine follow-up visits. By integrating OCT-based measurements into daily practice, clinicians may identify early tear film instability and prevent contact lens intolerance. This is particularly relevant for younger patients who are at risk of long-term ocular surface changes due to extended lens wear.

CONCLUSION

A significant decrease in PLTF stability (NIAvgBUT) and PoLTF thickness in the central corneal area was observed after 2-4 weeks of CL use. These findings suggest that prolonged CL wear affects tear film stability and surface wettability, highlighting the importance of monitoring these changes over time.

Для цитирования: Arslan Neşe, Kakil Şule Barman. OCT-Based Analysis of Post-Lens Tear Film Stability in Silicone Hydrogel Contact Lenses.. Romanian journal of ophthalmology. 2025. DOI: 10.22336/rjo.2025.59.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.