Multimodal Evaluation of Arrhythmogenic Substrate Predicts Atrial Fibrosis and Atrial Fibrillation Recurrence After Catheter Ablation.
Аннотация
Background/
Objectives
For many years, catheter ablation (CA) has been a cornerstone in atrial fibrillation (AF) rhythm control therapy; however, recurrence remains common. Multiple parameters have been proposed to quantify AF arrhythmogenic substrate, yet reliable predictors of long-term outcomes are lacking. To assess the value of non-invasive amplified P-wave duration (PWD), echocardiographic parameters, biomarkers, and electroanatomical mapping (EAM) were used in predicting left atrial (LA) fibrosis and arrhythmia recurrence after CA.
Methods
We included 196 patients undergoing first CA for paroxysmal or persistent AF. Amplified 12-lead ECG PWD parameters [Pmax, Pmin and left atrial P-wave (LAP)], echocardiographic parameters, and biomarkers were assessed pre-procedure. We measured low-voltage areas (LVA, 0.2-0.5 mV) on high-density voltage EAM during sinus rhythm as a surrogate of fibrosis. Freedom from arrhythmia was evaluated at 6 and 12 months.
Results
Patients with LVA on EAM had prolonged Pmax (148 vs. 135 ms, p < 0.0001), Pmin (111 vs. 101.5 ms, p = 0.0001), LAP (73.5 vs. 55.5 ms, p < 0.0001), larger LA diameter (p = 0.0002), area (p = 0.0365) and volume (p = 0.004), higher E/E' (p = 0.0007) and E/A ratios (p = 0.037), more mitral regurgitation (p = 0.0315), and higher pro-BNP levels (p = 0.0094). Univariate analysis showed 12-month recurrence rates higher with greater Pmax, Pmin, LAP, LVA presence and extent; however, in multivariate analysis, only P-wave parameters remained independently associated with recurrence.
Conclusions
Prolonged PWD parameters strongly reflect LA substrate (Pmax, Pmin) and independently predict post-ablation AF recurrence (Pmax, Pmin, and LAP). LA size, diastolic dysfunction, and mitral regurgitation were associated with LA fibrosis, while pro-BNP was associated with both fibrosis and arrhythmia recurrence. Integrating these simple, non-invasive markers into a multimodal assessment alongside EAM could improve pre-procedural risk stratification and guide individualized ablation strategies.