MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000338964

Медицинская библиотека · Blood purification · 2012

Peritoneal dialysis as compared with hemodialysis is associated with higher overhydration but non-inferior blood pressure control and heart function.

Yao Yen-Hung, Fu Chun-Hsiang, Ho Shuenn-Jiin, Tsai Shin-Hung, Ng Yee-Yung, Chuang Chiao-Lin, Lin Chih-Chin, Chen Jinn-Yang

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Fluid overload is an important factor causing cardiovascular complications in dialysis patients. We compared fluid status, blood pressure (BP) and heart function between peritoneal dialysis (PD) patients and hemodialysis (HD) patients.

METHODS

We recruited 94 PD and 75 HD patients in our hospital. Fluid status was assessed by bioimpedance spectroscopy. Home BP was recorded. Use of antihypertensives was retrieved by chart review. In each group, 39 patients received echocardiographic examinations.

RESULTS

PD patients' fluid status was similar to that of predialysis HD patients. PD patients had lower systolic BP. E/E' and left ventricular mass index (LVMI) showed no significant intergroup difference. In multiple linear regression analyses, overhydration (OH)/extracellular water ratio >0.15 was associated with higher systolic BP, E/E' and LVMI.

CONCLUSIONS

While PD was associated with higher OH but non-inferior BP control and heart function, OH was indeed related to poor BP control, diastolic dysfunction and left ventricular hypertrophy.

Для цитирования: Yao Yen-Hung, Fu Chun-Hsiang, Ho Shuenn-Jiin, Tsai Shin-Hung, Ng Yee-Yung, Chuang Chiao-Lin, Lin Chih-Chin, Chen Jinn-Yang. Peritoneal dialysis as compared with hemodialysis is associated with higher overhydration but non-inferior blood pressure control and heart function.. Blood purification. 2012. DOI: 10.1159/000338964.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.