A Novel Approach for Suprachoroidal Space Injection: An Experimental Evaluation.

Long Jinyi, Wu Xue, Hu Ping, Cui Ning, Xu Ling, Ye Yuhong, Chen Hao, Peng Qinghua, Lu Xinmin, Long Da

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aims to describe an innovative suprachoroidal space injection technique using a combination of 30 G and 22 G needles attached to a 1 ml injector. The efficacy and applicability of this technique in suprachoroidal injections are evaluated.

METHODS

In this study, we conducted both in vitro and in vivo injection experiments using isolated porcine eyes and live SD rats, respectively. The injector needle was inserted into the sclera with the bevelled tip facing the sclera and parallel to the corneal limbus, and the methylene blue solution was injected into the suprachoroidal space. The accuracy of the injection was confirmed by OCT imaging and frozen section microscopy, demonstrating that the dye was successfully delivered to the suprachoroidal space.

RESULTS

The suprachoroidal injector successfully injected the solution into the suprachoroidal space of isolated porcine eyes and live rats without entering the vitreous cavity.

CONCLUSION

The 22 G needle demonstrated sufficient rigidity and stability to ensure proper scleral compression, supporting the consistency of the injection depth. The 30 G needle exhibited exceptional sharpness and precision, allowing for more accurate control of the drug dosage. The appropriate force applied to the sclera facilitated the precise depth of injection. The angle of the needle, parallel to the corneal limbus, helped avoid penetration into the vitreous or subretinal space, reducing the risk of complications. This device offers new tools and methods for ophthalmic research and clinical practice, with significant clinical application prospects.

Для цитирования: Long Jinyi, Wu Xue, Hu Ping, Cui Ning, Xu Ling, Ye Yuhong, Chen Hao, Peng Qinghua, Lu Xinmin, Long Da. A Novel Approach for Suprachoroidal Space Injection: An Experimental Evaluation.. Current eye research. 2025. DOI: 10.1080/02713683.2025.2469829.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.