MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ons/opx260

Медицинская библиотека · Operative neurosurgery (Hagerstown, Md.) · 2018

Usefulness of Sealants for Dural Closure: Evaluation in an In Vitro Model.

van Doormaal Tristan, Kinaci Ahmet, van Thoor Sander, Redegeld Saskia, Bergmann Wilhelmina, van der Zwan Albert

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cerebrospinal fluid (CSF) leakage occurs in 4% to 32% of cranial surgeries and is associated with significant patient burden and expense. The use of sealant as an adjunct to primary dural closure is assumed to help prevent CSF leakage.

OBJECTIVE

To examine the utility of different sealants for dural closure using an in Vitro model.

METHODS

We evaluated 9 commonly used dural sealants, including Tachosil (Takeda Inc, Osaka, Japan), Adherus (Hyperbranch Inc, Durham, North Carolina), Duraform (Codman, Raynham, Massachusetts), Tissudura (Baxter, Deerfield, Illinois), Hemopatch (Baxter), TissuePatchDural (Tissuemed, Leeds, United Kingdom), Tisseel (Baxter), Duragen Secure (Integra, Plainsboro, New Jersey), and Duraseal, (Integra). Sealants were tested in 2 novel in Vitro setups using fresh porcine dura: the first tested the acute burst pressure of a sealed 3-mm gap, while the second examined resistance to a pressure wave mimicking intracranial pressure for 72 h.

RESULTS

Adherus showed the highest mean burst pressure (87 ± 47 mmHg) followed by Tachosil (71 ± 16 mmHg) and Duraseal (51 ± 42 mmHg); these were the only 3 sealants showing burst pressures above normal physiological intracranial pressure. In the 72-h setup, only Adherus and Duraseal maintained appropriate sealing for the duration of the experiment. Tachosil released from the dura after 1.4 h (95% confidence interval, -1.8-4.7).

CONCLUSION

Given the high cost of sealants and the results of this study, we advocate a critical attitude toward sealant application as an adjunct to classic dural closure.

Для цитирования: van Doormaal Tristan, Kinaci Ahmet, van Thoor Sander, Redegeld Saskia, Bergmann Wilhelmina, van der Zwan Albert. Usefulness of Sealants for Dural Closure: Evaluation in an In Vitro Model.. Operative neurosurgery (Hagerstown, Md.). 2018. DOI: 10.1093/ons/opx260.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.