Biochemia medica · 2017
Tau protein as a possible marker of cerebrospinal fluid leakage in cerebrospinal fluid rhinorrhoea: A pilot study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Oudart Jean-Baptiste, Zucchini Laure, Maquart François-Xavier, Dubernard Xavier, Labrousse Marc, Fiabane Géraldine, Quedreux Alexandra, Litre Fabien, Ramont Laurent
Аннотация
INTRODUCTION: The management of posttraumatic cerebrospinal fluid (CSF) rhinorrhoea remains a clinical challenge. Cerebrospinal fistula is a dural defect responsible for possible CSF leakage into the contiguous air-filled cavities located at the skull base. The risk of central nervous system infection in these conditions is severe and can be life threatening. Consequently, a specific CSF biomarker might be used in case of difficult diagnosis of CSF rhinorrhoea. CSF Tau protein is a neuronal protein, commonly assessed for diagnosis of Alzheimer Disease (AD). The aim of this study was to determine whether the Tau protein could be a relevant marker of CSF leakage.
MATERIALS AND METHODS: Tau protein measurement was performed by enzyme-linked immunosorbent assay in 13 patients with CSF leakage (CSF rhinorrhoea group), and 8 patients with spontaneous aqueous rhinorrhoea (non-CSF leakage group). The serum concentration of Tau protein was measured by ELISA in both CSF rhinorrhoea group and non-CSF leakage group.
RESULTS: In patients with CSF leakage, CSF Tau protein median concentration was 479 ng/L (197 - 2325 ng/L). On the other hand, the Tau protein concentration was below the lower limit of quantification (LLoQ) (< 87 ng/L) in non-CSF leakage group. Serum Tau protein concentration by ELISA was also below LLoQ (< 87 ng/L) for all subjects.
CONCLUSION: ELISA measurement of Tau protein in rhinorrhoea fluid may be a reliable and relevant marker for detecting the presence of CSF in the nasal discharge and sign the existence of a CSF leakage.
MATERIALS AND METHODS: Tau protein measurement was performed by enzyme-linked immunosorbent assay in 13 patients with CSF leakage (CSF rhinorrhoea group), and 8 patients with spontaneous aqueous rhinorrhoea (non-CSF leakage group). The serum concentration of Tau protein was measured by ELISA in both CSF rhinorrhoea group and non-CSF leakage group.
RESULTS: In patients with CSF leakage, CSF Tau protein median concentration was 479 ng/L (197 - 2325 ng/L). On the other hand, the Tau protein concentration was below the lower limit of quantification (LLoQ) (< 87 ng/L) in non-CSF leakage group. Serum Tau protein concentration by ELISA was also below LLoQ (< 87 ng/L) for all subjects.
CONCLUSION: ELISA measurement of Tau protein in rhinorrhoea fluid may be a reliable and relevant marker for detecting the presence of CSF in the nasal discharge and sign the existence of a CSF leakage.