Artificial organs · 2016

What Is the Optimal Setting for a Continuous-Flow Left Ventricular Assist Device in Severe Mitral Regurgitation?

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Naito Noritsugu, Nishimura Takashi, Takewa Yoshiaki, Kishimoto Satoru, Date Kazuma, Umeki Akihide, Ando Masahiko, Ono Minoru, Tatsumi Eisuke

Аннотация

Excessive left ventricular (LV) volume unloading can affect right ventricular (RV) function by causing a leftward shift of the interventricular septum in patients with mitral regurgitation (MR) receiving left ventricular assist device (LVAD) support. Optimal settings for the LVAD should be chosen to appropriately control the MR without causing RV dysfunction. In this study, we assessed the utility of our electrocardiogram-synchronized rotational speed (RS) modulation system along with a continuous-flow LVAD in a goat model of MR. We implanted EVAHEART devices after left thoracotomy in six adult goats weighing 66.4 ± 10.7 kg. Severe MR was induced through inflation of a temporary inferior vena cava filter placed within the mitral valve. We evaluated total flow (TF; the sum of aortic flow and pump flow [PF]), RV fractional area change (RVFAC) calculated by echocardiography, left atrial pressure (LAP), LV end-diastolic pressure (LVEDP), LV end-diastolic volume (LVEDV), and LV stroke work (LVSW) with a bypass rate (PF divided by TF) of 100% under four conditions: circuit-clamp, continuous mode, co-pulse mode (increased RS during systole), and counter-pulse mode (increased RS during diastole). TF tended to be higher in the counter-pulse mode. Moreover, RVFAC was significantly higher in the counter-pulse mode than in the co-pulse mode, whereas LAP was significantly lower in all driving modes than in the circuit-clamp condition. Furthermore, LVEDP, LVEDV, and LVSW were significantly lower in the counter-pulse mode than in the circuit-clamp condition. The counter-pulse mode of our RS modulation system used with a continuous-flow LVAD may offer favorable control of MR while minimizing RV dysfunction.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты