MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2022.110387

Медицинская библиотека · European journal of radiology · 2022

Ultrasonographic measurement of abdominal and gluteal-femoral fat thickness as a predictor for android/gynoid ratio.

Prasetyo Marcel, Andreas Steven, Sunardi Diana, Prihartono Joedo, Imanuel Setiawan Stefanus, Christian Andreas

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the use of ultrasonography (US) as an alternative to dual-energy x-ray absorptiometry (DXA) to predict the percentage ratio of android/gynoid (A/G) fat mass.

METHODS

This was a cross-sectional study. Twenty-eight participants included in the study underwent whole-body DXA examinations and the A/G ratio was calculated. Soft-tissue US was performed in several standardised anthropometric areas of the body. Correlation analysis between abdominal and gluteal-femoral fat thickness based on US and A/G ratio was conducted using the Pearson or Spearman test depending on the data normality. Multiple regression analysis using the backward stepwise method was performed to establish an equation for estimating the A/G ratio.

RESULTS

There was a strong and significant correlation between fat thickness in the six anthropometric areas and the A/G ratio in female participants. The analysis revealed three anthropometric areas: upper abdomen (S4), lower abdomen (S5), and mid-xiphoid-umbilical region (S7), that can accurately predict the A/G ratio by 82.3%. (P < 0.05). However, no such correlation was found in male participants.

CONCLUSIONS

US measurement of fat thickness can predict A/G ratio in the female population. However, this method is not recommended for men.

Для цитирования: Prasetyo Marcel, Andreas Steven, Sunardi Diana, Prihartono Joedo, Imanuel Setiawan Stefanus, Christian Andreas. Ultrasonographic measurement of abdominal and gluteal-femoral fat thickness as a predictor for android/gynoid ratio.. European journal of radiology. 2022. DOI: 10.1016/j.ejrad.2022.110387.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.