MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-020-01655-y

Медицинская библиотека · BMC ophthalmology · 2020

Comparison of ultrasound cycloplasty and transscleral cyclophotocoagulation for refractory glaucoma in Chinese population.

Yu Qiuli, Liang Ya, Ji Fangfang, Yuan Zhilan

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To compare the efficacy and safety of focused ultrasound cycloplasty (UCP) and transscleral cyclophotocoagulation (TSCP) in the treatment of refractory glaucoma in a Chinese population.

METHODS

We retrospectively compared twenty-eight eligible patients with refractory glaucoma, who were divided into the UCP group and TSCP group. Patients in these two groups underwent a corresponding procedure from June 2018 to February 2019. The intraocular pressure (IOP), visual acuity, the number of anti-glaucoma agents used and complications were reviewed and compared between groups. Proper statistical methods were selected according to comparison models under IBM SPSS 25 software.

RESULTS

After the 12-months follow-up, postoperative IOP and number of anti-glaucoma agents used in the two groups were both reduced than the baseline level, and the differences were statistically significant (P < 0.05). There were no significant differences in IOP, number of anti-glaucoma agents and the best-corrected visual acuity between the two groups at each follow-up time point (P>0.05). In terms of complications, the pain at 1 day after surgery in the UCP group was significantly milder than that in the TSCP group (P < 0.05). And there were no significant differences in other complications between the two groups (P > 0.05).

CONCLUSIONS

Both UCP and TSCP are safe and effective methods for the treatment of refractory glaucoma. Nevertheless, pain is less severe after UCP.

Для цитирования: Yu Qiuli, Liang Ya, Ji Fangfang, Yuan Zhilan. Comparison of ultrasound cycloplasty and transscleral cyclophotocoagulation for refractory glaucoma in Chinese population.. BMC ophthalmology. 2020. DOI: 10.1186/s12886-020-01655-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.