m+Medelevator.RU
← Поиск публикаций
Analytical chemistry · 2026

An Entropy-Driven Autocatalysis-Regulated Signal-On CRISPR/Cas12a Biosensor Supported by DNA Triangular Prism Scaffold.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yang Li, Zhou Ya, Li Huimin, Chen Xin, Zhang Shu, Zhu Liping

Аннотация

Accurate and sensitive detection of low-abundance biomarkers in complex matrices remains challenging due to the inherent trade-off between amplification efficiency and background suppression in conventional biosensing strategies. Herein, a synergistic amplification strategy was constructed by integrating an entropy-driven autocatalysis (EDAC), a signal-on CRISPR/Cas12a assay, and a DNA triangular prism (DTP) interface. In this strategy, EDAC achieved exponential signal amplification through the recycling of target molecules and reaction byproducts, and its output strands simultaneously served as specific inhibitors of CRISPR/Cas12a. Based on this mechanism, the signal-on CRISPR/Cas12a assay strictly coupled signal generation to the presence of the target, thereby fundamentally circumventing the high background interference inherent to conventional signal-off modes. As a rigid three-dimensional interfacial scaffold, DTP provided high-density and well-ordered nucleic acid assembly sites, reduced steric hindrance through a solution-like microenvironment, suppressed nonspecific adsorption, and efficiently initiated downstream hybridization chain reaction for robust electrochemical readout via methylene blue intercalation. With hepatocellular carcinoma-associated biomarkers alpha-fetoprotein and microRNA-122 as model targets, the biosensor achieved detection limits as low as 11.37 fg/mL and 18.13 aM, respectively. In clinical serum sample assays, the biosensor showed strong agreement with the classical ELISA method, with an area under the curve value of 1.00, demonstrating its promising potential for the diagnosis of hepatocellular carcinoma. With its modular architecture and adaptable recognition elements, this strategy establishes a versatile framework for ultrasensitive biosensing and holds promise for clinical translation in early disease diagnosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты