MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/aln.0000000000003189

Медицинская библиотека · Anesthesiology · 2020

Does Iso-mechanical Power Lead to Iso-lung Damage?: An Experimental Study in a Porcine Model.

Vassalli Francesco, Pasticci Iacopo, Romitti Federica, Duscio Eleonora, Aßmann David Jerome, Grünhagen Hannah, Vasques Francesco, Bonifazi Matteo, Busana Mattia, Macrì Matteo Maria, Giosa Lorenzo, Reupke Verena, Herrmann Peter, Hahn Günter, Leopardi Orazio, Moerer Onnen, Quintel Michael, Marini John J, Gattinoni Luciano

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Excessive tidal volume, respiratory rate, and positive end-expiratory pressure (PEEP) are all potential causes of ventilator-induced lung injury, and all contribute to a single variable: the mechanical power. The authors aimed to determine whether high tidal volume or high respiratory rate or high PEEP at iso-mechanical power produce similar or different ventilator-induced lung injury.

METHODS

Three ventilatory strategies-high tidal volume (twice baseline functional residual capacity), high respiratory rate (40 bpm), and high PEEP (25 cm H2O)-were each applied at two levels of mechanical power (15 and 30 J/min) for 48 h in six groups of seven healthy female piglets (weight: 24.2 ± 2.0 kg, mean ± SD).

RESULTS

At iso-mechanical power, the high tidal volume groups immediately and sharply increased plateau, driving pressure, stress, and strain, which all further deteriorated with time. In high respiratory rate groups, they changed minimally at the beginning, but steadily increased during the 48 h. In contrast, after a sudden huge increase, they decreased with time in the high PEEP groups. End-experiment specific lung elastance was 6.5 ± 1.7 cm H2O in high tidal volume groups, 10.1 ± 3.9 cm H2O in high respiratory rate groups, and 4.5 ± 0.9 cm H2O in high PEEP groups. Functional residual capacity decreased and extravascular lung water increased similarly in these three categories. Lung weight, wet-to-dry ratio, and histologic scores were similar, regardless of ventilatory strategies and power levels. However, the alveolar edema score was higher in the low power groups. High PEEP had the greatest impact on hemodynamics, leading to increased need for fluids. Adverse events (early mortality and pneumothorax) also occurred more frequently in the high PEEP groups.

CONCLUSIONS

Different ventilatory strategies, delivered at iso-power, led to similar anatomical lung injury. The different systemic consequences of high PEEP underline that ventilator-induced lung injury must be evaluated in the context of the whole body.

Для цитирования: Vassalli Francesco, Pasticci Iacopo, Romitti Federica, Duscio Eleonora, Aßmann David Jerome, Grünhagen Hannah, Vasques Francesco, Bonifazi Matteo, Busana Mattia, Macrì Matteo Maria, Giosa Lorenzo, Reupke Verena, Herrmann Peter, Hahn Günter, Leopardi Orazio, Moerer Onnen, Quintel Michael, Marini John J, Gattinoni Luciano. Does Iso-mechanical Power Lead to Iso-lung Damage?: An Experimental Study in a Porcine Model.. Anesthesiology. 2020. DOI: 10.1097/aln.0000000000003189.