m+Medelevator.RU
← Поиск публикаций
Surgical endoscopy · 2020

Augmented fluoroscopic bronchoscopy (AFB) versus percutaneous computed tomography-guided dye localization for thoracoscopic resection of small lung nodules: a propensity-matched study.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yang Shun-Mao, Chen Yi-Chang, Ko Wei-Chun, Huang Hsin-Chieh, Yu Kai-Lun, Ko Huan-Jang, Huang Pei-Ming, Chang Yeun-Chung

Аннотация

BACKGROUND: Dye localization is a useful method for the resection of unidentifiable small pulmonary lesions. This study compares the transbronchial route with augmented fluoroscopic bronchoscopy (AFB) and conventional transthoracic CT-guided methods for preoperative dye localization in thoracoscopic surgery.

METHODS: Between April 2015 and March 2019, a total of 231 patients with small pulmonary lesions who received preoperative dye localization via AFB or percutaneous CT-guided technique were enrolled in the study. A propensity-matched analysis, incorporating preoperative variables, was used to compare localization and surgical outcomes between the two groups.

RESULTS: After matching, a total of 90 patients in the AFB group (N = 30) and CT-guided group (N = 60) were selected for analysis. No significant difference was noted in the demographic data between both the groups. Dye localization was successfully performed in 29 patients (96.7%) and 57 patients (95%) with AFB and CT-guided method, respectively. The localization duration (24.1 ± 8.3 vs. 21.4 ± 12.5 min, p = 0.297) and equivalent dose of radiation exposure (3.1 ± 1.5 vs. 2.5 ± 2.0 mSv, p = 0.130) were comparable in both the groups. No major procedure-related complications occurred in either group; however, a higher rate of pneumothorax (0 vs. 16.7%, p = 0.029) and focal intrapulmonary hemorrhage (3.3 vs. 26.7%, p = 0.008) was noted in the CT-guided group.

CONCLUSION: AFB dye marking is an effective alternative for the preoperative localization of small pulmonary lesions, with a lower risk of procedure-related complications than the conventional CT-guided method.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты