MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000504183

Медицинская библиотека · Respiration; international review of thoracic diseases · 2019

Efficacy of the Spiration Valve System in Patients with Severe Heterogeneous Emphysema: A Systematic Review and Meta-Analysis.

Majid Adnan, Labarca Gonzalo, Uribe Juan Pablo, Kheir Fayez, Pacheco Cecilia, Folch Erik, Jantz Michael A, Mehta Hiren J, Patel Neal M, Herth Felix J F, Fernandez-Bussy Sebastian

МетаанализСистематический обзорСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Spiration Valve System (SVS) is an alternative for patients with severe heterogeneous emphysema; however, data about efficacy from randomized controlled trials (RCT) are unclear.

OBJECTIVES

To explore both efficacy and safety of SVS in patients with severe emphysema and hyperinflation.

METHODS

We included PubMed, EMBASE, Coch-rane database. All searches were performed until August 2019. Only RCTs were included for analysis. Risk of bias was assessed using Cochrane risk of bias tool. A meta-analysis evaluated change in forced expiratory volume in 1 s (FEV1), 6-min walking test (6MWT), residual volume, modified medical research council (mMRC) and Saint George respiratory questionnaire (SGRQ), all-cause mortality, risk of pneumothorax, and risk of acute exacerbation of chronic obstructive pulmonary disease (AECOPD). Quality of the evidence was rated using GRADE approach.

RESULTS

Four RCTs including 629 subjects were included. SVS showed an overall change of 0.03 L (-0.07 to 0.13, I2 = 90%) in the in FEV1 (L) and a 2.03% (-2.50 to 6.57, I2 = 96%) in the predicted FEV1 (%) compared to baseline; however, studies without collateral ventilation (CV) showed an improvement of 0.12 L (95% CI 0.09-0.015, I2 = 0%), This subgroup also reported better results in SGRQ -12.27 points (95% CI -15.84 to -8.70, I2 = 0%) and mMRC -0.54 (95% CI -0.74 to -0.33, I2 = 0%). We found no benefit in 6MWT mean difference = 4.56 m (95% CI -21.88 to 31.00, I2 = 73%). Relative risk of mortality was 2.54 (95% CI 0.81-7.96, I2 = 0%), for pneumothorax 3.3 (95% CI 0.61-18.12, I2 = 0%) and AECOPD 1.68 (95% CI 1.04-2.70, I2 = 0%).

CONCLUSION

In patients with severe heterogeneous emphysema and hyperinflation without CV, SVS is an alternative that showed an improvement in pulmonary function, quality of life, and dyspnea score with an acceptable risk profile.

Для цитирования: Majid Adnan, Labarca Gonzalo, Uribe Juan Pablo, Kheir Fayez, Pacheco Cecilia, Folch Erik, Jantz Michael A, Mehta Hiren J, Patel Neal M, Herth Felix J F, Fernandez-Bussy Sebastian. Efficacy of the Spiration Valve System in Patients with Severe Heterogeneous Emphysema: A Systematic Review and Meta-Analysis.. Respiration; international review of thoracic diseases. 2019. DOI: 10.1159/000504183.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.