MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2017.08.011

Медицинская библиотека · Journal of biomechanics · 2017

Microcirculation in the murine liver: a computational fluid dynamic model based on 3D reconstruction from in vivo microscopy.

Piergiovanni Monica, Bianchi Elena, Capitani Giada, Li Piani Irene, Ganzer Lucia, Guidotti Luca G, Iannacone Matteo, Dubini Gabriele

СтатьяПеревод пока не подготовлен

Аннотация

The liver is organized in hexagonal functional units - termed lobules - characterized by a rather peculiar blood microcirculation, due to the presence of a tangled network of capillaries - termed sinusoids. A better understanding of the hemodynamics that governs liver microcirculation is relevant to clinical and biological studies aimed at improving our management of liver diseases and transplantation. Herein, we built a CFD model of a 3D sinusoidal network, based on in vivo images of a physiological mouse liver obtained with a 2-photon microscope. The CFD model was developed with Fluent 16.0 (ANSYS Inc., Canonsburg, PA), particular care was taken in imposing the correct boundary conditions representing a physiological state. To account for the remaining branches of the sinusoids, a lumped parameter model was used to prescribe the correct pressure at each outlet. The effect of an adhered cell on local hemodynamics is also investigated for different occlusion degrees. The model here proposed accurately reproduces the fluid dynamics in a portion of the sinusoidal network in mouse liver. Mean velocities and mass flow rates are in agreement with literature values from in vivo measurements. Our approach provides details on local phenomena, hardly described by other computational studies, either focused on the macroscopic hepatic vasculature or based on homogeneous porous medium model.

Для цитирования: Piergiovanni Monica, Bianchi Elena, Capitani Giada, Li Piani Irene, Ganzer Lucia, Guidotti Luca G, Iannacone Matteo, Dubini Gabriele. Microcirculation in the murine liver: a computational fluid dynamic model based on 3D reconstruction from in vivo microscopy.. Journal of biomechanics. 2017. DOI: 10.1016/j.jbiomech.2017.08.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.