Decoupling Between Diastolic Pulmonary Artery Pressure and Pulmonary Capillary Wedge Pressure as a Prognostic Factor After Continuous Flow Ventricular Assist Device Implantation.

Imamura Teruhiko, Chung Ben, Nguyen Ann, Rodgers Daniel, Sayer Gabriel, Adatya Sirtaz, Sarswat Nitasha, Kim Gene, Raikhelkar Jayant, Ota Takeyohi, Song Tae, Juricek Colleen, Kagan Viktoriya, Jeevanandam Valluvan, Mehra Mandeep, Burkhoff Daniel, Uriel Nir

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

A cohort of heart failure (HF) patients receiving left ventricular assist devices (LVADs) has decoupling of their diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. However, the clinical implications of this decoupling remain unclear.

METHODS AND

RESULTS

In this prospective study, patients with LVADs underwent routine invasive hemodynamic ramp testing with right heart catheterization, during which LVAD speeds were adjusted. Inappropriate decoupling was defined as a >5 mm Hg difference between diastolic pulmonary artery pressure and pulmonary capillary wedge pressure. The primary outcomes of survival and heart failure readmission rates after ramp testing were assessed. Among 63 LVAD patients (60±12 years old and 25 female [40%]), 27 patients (43%) had inappropriate decoupling at their baseline speed. After adjustment of their rotation speed during ramp testing, 30 patients (48%) had inappropriate decoupling. Uni/multivariable Cox analyses demonstrated that decoupling was the only significant predictor for the composite end point of death and heart failure readmission during the 1 year following the ramp study (total of 18 events; hazards ratio, 1.09; 95% confidence interval, 1.04-1.24; P<0.05). Furthermore, normalization of decoupling (n=8) during ramp testing was significantly associated with higher 1-year heart failure readmission-free survival rate compared with the non-normalized group (n=19, 100% versus 53%; P=0.035).

CONCLUSIONS

The presence of inappropriate decoupling was associated with worse outcomes in patients with LVADs. Prospective, large-scale multicenter studies to validate the result are warranted.

Для цитирования: Imamura Teruhiko, Chung Ben, Nguyen Ann, Rodgers Daniel, Sayer Gabriel, Adatya Sirtaz, Sarswat Nitasha, Kim Gene, Raikhelkar Jayant, Ota Takeyohi, Song Tae, Juricek Colleen, Kagan Viktoriya, Jeevanandam Valluvan, Mehra Mandeep, Burkhoff Daniel, Uriel Nir. Decoupling Between Diastolic Pulmonary Artery Pressure and Pulmonary Capillary Wedge Pressure as a Prognostic Factor After Continuous Flow Ventricular Assist Device Implantation.. Circulation. Heart failure. 2017. DOI: 10.1161/circheartfailure.117.003882.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.