MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2024.08.035

Медицинская библиотека · American journal of ophthalmology · 2024

Results of Lucia Keratoprosthesis Implantation in Severe Corneal Disease.

Ortiz-Morales Gustavo, Vera-Duarte Guillermo Raul, Jimenez-Collado David, Rivera Jose Arteaga, Rivera Karla Arteaga, Domene-Hickman Jorge Luis, Müller-Morales Carlos Adolfo, Navas Alejandro, Ramirez-Miranda Arturo, Chodosh James, Graue-Hernandez Enrique O

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Describe complications, functional success, and retention of the Lucia Keratoprosthesis (KPro).

DESIGN

Retrospective interventional case series

METHODS

The demographic data, baseline characteristics, complications, functional success, and retention were analyzed for Lucia KPro at the Instituto de Oftalmologia Conde de Valenciana in Mexico City from 2021 to 2023. Multivariate regression analysis and Kaplan-Meier plots were performed to identify associations with functional failure. The main outcome measures were postoperative complications, functional success defined as best-corrected visual acuity (BCVA) ≥20/200 (logMAR 1.0), and device retention rate.

RESULTS

Forty-eight eyes of 48 patients (56.88% male) were studied. The mean age at implantation was 57.29 ± 15.63 years (range 27-91), with a mean follow-up of 20.5 ± 8.83 months (range 3-40). Diagnostic indications for implantation included recurrent graft rejection (54.17%), autoimmune disease (20.83%), chemical injury (12.5%), and other (12.5%). At least 1 postoperative complication occurred in 75% of patients, leading to 65 additional interventions (mean number of subsequent procedures: 1.35 ± 1.3, range 0-5). The preoperative BCVA was 2.40 ± 0.36 logMAR. At the final follow-up, 62.5% had achieved functional success and 22.92% had a BCVA of 20/40 (logMAR 0.3) or better. Glaucoma (adjusted OR 469.74, 95% CI 5.02-43939.14, P = .007) and retinal pathology before KPro (adjusted OR 372.38, 95% CI 4.18-33162.11, P = .009) were associated with functional failure. The device remained in place in 95.83% of recipients over the follow-up period.

CONCLUSIONS

The Lucia KPro offers functional success in severe corneal diseases and excellent retention in the short to intermediate term.

Для цитирования: Ortiz-Morales Gustavo, Vera-Duarte Guillermo Raul, Jimenez-Collado David, Rivera Jose Arteaga, Rivera Karla Arteaga, Domene-Hickman Jorge Luis, Müller-Morales Carlos Adolfo, Navas Alejandro, Ramirez-Miranda Arturo, Chodosh James, Graue-Hernandez Enrique O. Results of Lucia Keratoprosthesis Implantation in Severe Corneal Disease.. American journal of ophthalmology. 2024. DOI: 10.1016/j.ajo.2024.08.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.