Journal of neurophysiology · 2026

The effects of electrode configuration and location on motor thresholds, tolerance, and muscle selectivity of transcutaneous spinal cord stimulation in stroke.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Veit Nicole C, Aalla Shreya, Kishta Ameen, McKenzie Kelly A, Yang Chen, Tillman Mitchell, Roth Elliot J, Lieber Richard L, Jayaraman Arun

Аннотация

Identifying optimal conditions for transcutaneous spinal cord stimulation (tSCS), such as electrode configuration, is essential for clinical translation, particularly as this promising neuromodulation therapy expands to include diverse neurological populations. However, before clinical application, it is important to understand how different configurations affect dosage and muscle recruitment. We define dosage as the percentage of the current needed to elicit a motor response (the resting motor threshold, or RMT) of the current value tolerated during walking when stimulation is delivered continuously. Another consideration is whether electrode configurations can selectively recruit specific muscles, potentially guiding tSCS protocols to prioritize the muscles most critical for functional improvement. This study tested five electrode configurations in individuals with chronic stroke: one round electrode at T11-T12 vertebrae, one round electrode at L1-L2, two separate round electrodes at T11-T12 and L1-L2 from separate current channels, two separate round electrodes at T11-T12 and L1-L2 from the same current channel, and a rectangular electrode spanning T11-T12 and L1-L2. No single electrode configuration clearly outperformed others in terms of tolerated dosage, with most supporting stimulation near 50% of RMT except the two-channel setup with separate current channels, which showed lower dosage (∼35% RMT). Additionally, muscle selectivity did not significantly differ across configurations. These findings inform stimulation dosage feasibility for future tSCS protocols using different electrode configurations and the need for future studies to evaluate whether current dosage levels are adequate to induce meaningful neuromodulation and clinical benefits in the stroke population.NEW & NOTEWORTHY This is the first study to examine how electrode configuration influences stimulation comfort in transcutaneous spinal cord stimulation (tSCS) relative to resting motor threshold (RMT) in individuals with stroke. Across five configurations, most were tolerated at ∼50% RMT, whereas a two-channel setup reduced tolerance (∼35%). Muscle selectivity did not differ significantly among configurations. These findings establish critical feasibility benchmarks for electrode placement in future tSCS protocols for stroke rehabilitation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты