Baggiano Andrea, Conte Edoardo, Spiritigliozzi Luigi, Mushtaq Saima, Annoni Andrea, Carerj Maria Ludovica, Cilia Francesco, Fazzari Fabio, Formenti Alberto, Frappampina Antonio, Fusini Laura, Gaudenzi Asinelli Margherita, Junod Daniele, Mancini Maria Elisabetta, Mantegazza Valentina, Maragna Riccardo, Marchetti Francesca, Penso Marco, Tassetti Luigi, Volpe Alessandra, Baessato Francesca, Guglielmo Marco, Rossi Alexia, Rovera Chiara, Andreini Daniele, Rabbat Mark G, Guaricci Andrea Igoren, Pepi Mauro, Pontone Gianluca

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac computed tomography (CCT) was recently validated to measure extracellular volume (ECV) in the setting of cardiac amyloidosis, showing good agreement with cardiovascular magnetic resonance (CMR). However, no evidence is available with a whole-heart single source, single energy CT scanner in the clinical context of newly diagnosed left ventricular dysfunction. Therefore, the aim of this study was to test the diagnostic accuracy of ECVCCT in patients with a recent diagnosis of dilated cardiomyopathy, having ECVCMR as the reference technique.

METHODS

39 consecutive patients with newly diagnosed dilated cardiomyopathy (LVEF <50%) scheduled for clinically indicated CMR were prospectively enrolled. Myocardial segment evaluability assessment with each technique, agreement between ECVCMR and ECVCCT, regression analysis, Bland-Altman analysis and interclass correlation coefficient (ICC) were performed.

RESULTS

Mean age of enrolled patients was 62 ​± ​11 years, and mean LVEF at CMR was 35.4 ​± ​10.7%. Overall radiation exposure for ECV estimation was 2.1 ​± ​1.1 ​mSv. Out of 624 myocardial segments available for analysis, 624 (100%) segments were assessable by CCT while 608 (97.4%) were evaluable at CMR. ECVCCT demonstrated slightly lower values compared to ECVCMR (all segments, 31.8 ​± ​6.5% vs 33.9 ​± ​8.0%, p ​< ​0.001). At regression analysis, strong correlations were described (all segments, r ​= ​0.819, 95% CI: 0.791 to 0.844). On Bland-Altman analysis, bias between ECVCMR and ECVCCT for global analysis was 2.1 (95% CI: -6.8 to 11.1). ICC analysis showed both high intra-observer and inter-observer agreement for ECVCCT calculation (0.986, 95%CI: 0.983 to 0.988 and 0.966, 95%CI: 0.960 to 0.971, respectively).

CONCLUSIONS

ECV estimation with a whole-heart single source, single energy CT scanner is feasible and accurate. Integration of ECV measurement in a comprehensive CCT evaluation of patients with newly diagnosed dilated cardiomyopathy can be performed with a small increase in overall radiation exposure.

Для цитирования: Baggiano Andrea, Conte Edoardo, Spiritigliozzi Luigi, Mushtaq Saima, Annoni Andrea, Carerj Maria Ludovica, Cilia Francesco, Fazzari Fabio, Formenti Alberto, Frappampina Antonio, Fusini Laura, Gaudenzi Asinelli Margherita, Junod Daniele, Mancini Maria Elisabetta, Mantegazza Valentina, Maragna Riccardo, Marchetti Francesca, Penso Marco, Tassetti Luigi, Volpe Alessandra, Baessato Francesca, Guglielmo Marco, Rossi Alexia, Rovera Chiara, Andreini Daniele, Rabbat Mark G, Guaricci Andrea Igoren, Pepi Mauro, Pontone Gianluca. Quantification of extracellular volume with cardiac computed tomography in patients with dilated cardiomyopathy.. Journal of cardiovascular computed tomography. 2023. DOI: 10.1016/j.jcct.2023.04.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.