Pieterman E D, Liqui Lung F G, Verbon A, Bax H I, Ang C W, Berkhout J, Blaauw G, Brandenburg A, van Burgel N D, Claessen A, van Dijk K, Heron M, Hooghiemstra M, Leussenkamp-Hummelink R, van Lochem E, van Loo I H M, Mulder B, Ott A, Pontesilli O, Reuwer A, Rombouts P, Saegeman V, Scholing M, Vainio S, de Steenwinkel J E M
Аннотация
OBJECTIVES: The aim of this verification study was to compare the QuantiFERON®-TB Gold Plus (QFT-Plus) to the QuantiFERON®-TB Gold In Tube (QFT-GIT). The new QFT-Plus test contains an extra antigen tube which, according to the manufacturer additionally elicits a CD8+ T-cell response above the CD4+ T-cell response. We assessed the value of this tube in detecting recent latent tuberculosis infections.
METHODS: Between May 2015 and December 2016, 1031 subjects underwent QFT-Plus and QFT-GIT test. Overall agreement between both tests and performance for different test indications and/or immune states was assessed. A difference of >0.6 IU/mL interferon-γ release between the two antigen tubes of the QFT-Plus assay was considered a true difference and used as estimation for CD8+ T-cell response.
RESULTS: Analysis of the QuantiFERON tests resulted in an overall agreement between assays of 95%. Subjects considered to be recently exposed to tuberculosis had significantly more often a true difference in interferon-γ release compared to all other subjects (p = 0.029).
CONCLUSION: Results of QFT-Plus are highly comparable to QFT-GIT. Although there is an indication that a true difference in interferon-γ release between the antigen tubes is associated with recent latent tuberculosis infection, the QFT-Plus could not be used to exclude recent exposure.
METHODS: Between May 2015 and December 2016, 1031 subjects underwent QFT-Plus and QFT-GIT test. Overall agreement between both tests and performance for different test indications and/or immune states was assessed. A difference of >0.6 IU/mL interferon-γ release between the two antigen tubes of the QFT-Plus assay was considered a true difference and used as estimation for CD8+ T-cell response.
RESULTS: Analysis of the QuantiFERON tests resulted in an overall agreement between assays of 95%. Subjects considered to be recently exposed to tuberculosis had significantly more often a true difference in interferon-γ release compared to all other subjects (p = 0.029).