MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjophthalmol-2018-313070

Медицинская библиотека · The British journal of ophthalmology · 2018

Clinical relevance of protruded retinal layers in minimum rim width measurement of the optic nerve head.

Torres Lucas A, Jarrar Faisal, Sharpe Glen P, Hutchison Donna M, Ferracioli-Oda Eduardo, Hatanaka Marcelo, Nicolela Marcelo T, Vianna Jayme R, Chauhan Balwantray C

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Optical coherence tomography (OCT) imaging of the optic nerve head minimum rim width (MRW) has recently been shown to sometimes contain components besides extended retinal nerve fibre layer (RNFL). This study was conducted to determine whether excluding these components, termed protruded retinal layers (PRLs), from MRW increases diagnostic accuracy for detecting glaucoma.

METHODS

In this cross-sectional study, we included 123 patients with glaucoma and 123 normal age-similar controls with OCT imaging of the optic nerve head (24 radial scans) and RNFL (circle scan). When present, PRLs were manually segmented, and adjusted MRW measurements were computed. We compared diagnostic accuracy of adjusted versus unadjusted MRW measurement. We also determined whether adjusted MRW correlates better with RNFL thickness compared with unadjusted MRW.

RESULTS

The median (IQR) visual field mean deviation of patients and controls was -4.4 (-10.3 to -2.1) dB and 0.0 (-0.6 to 0.8) dB, respectively. In the 5904 individual B-scans, PRLs were identified less frequently in patients (448, 7.6%) compared with controls (728, 12.3%; p<0.01) and were present most frequently in the temporal sector of both groups. Areas under the receiver operating characteristic curves and sensitivity values at 95% specificity indicated that PRL adjustment did not improve diagnostic accuracy of MRW, globally or temporally. Furthermore, adjusting MRW for PRL did not improve its correlation with RNFL thickness in either group.

CONCLUSION

While layers besides the RNFL are sometimes included in OCT measurements of MRW, subtracting these layers does not impact clinical utility.

Для цитирования: Torres Lucas A, Jarrar Faisal, Sharpe Glen P, Hutchison Donna M, Ferracioli-Oda Eduardo, Hatanaka Marcelo, Nicolela Marcelo T, Vianna Jayme R, Chauhan Balwantray C. Clinical relevance of protruded retinal layers in minimum rim width measurement of the optic nerve head.. The British journal of ophthalmology. 2018. DOI: 10.1136/bjophthalmol-2018-313070.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.