m+Medelevator.RU
← Поиск публикаций
International journal of psychophysiology : official journal of the International Organization of Psychophysiology · 2013

Blunted salivary and plasma cortisol response in patients with panic disorder under psychosocial stress.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Petrowski Katja, Wintermann Gloria-Beatrice, Schaarschmidt Marco, Bornstein Stefan R, Kirschbaum Clemens

Аннотация

BACKGROUND: Panic disorder (PD) has been associated with an altered activity of the hypothalamic-pituitary-adrenal-cortical (HPA) axis. Recent findings from a patient sample with PD with secondary depression on psychotropic medication using salivary cortisol as outcome measure suggest a non-responsiveness of the HPA-axis under acute psychosocial stress. Salivary cortisol does not necessarily reflect the total plasma cortisol due to interfering variables. Whether the present findings can be replicated on a patient sample with pure PD using both salivary cortisol and total plasma cortisol as outcome variables remains to be elucidated.

METHODS: For this study, the Trier Social Stress Test (TSST) was implemented to assess the HPA-axis reactivity indicated by the plasma adreno-corticotropin-hormone (ACTH), plasma cortisol, and salivary cortisol release. The sample included 32 patients diagnosed with PD in a Structured Clinical Interview (SCID). Twelve male and fifteen female patients [mean age=32.87years, SD=11.23] were matched with 32 healthy controls by age and gender.

RESULTS: The plasma ACTH, total plasma cortisol and salivary cortisol release increased significantly in both groups due to the psychosocial stress test. The patients with PD showed a decreased plasma and salivary cortisol response as compared to the healthy controls. Plasma cortisol and salivary cortisol were highly correlated in both groups.

CONCLUSION: These findings provide strong evidence for a hypo-responsiveness of the HPA-axis as measured in both blood and saliva. Salivary and total plasma cortisol showed a strong concordance of results. Thus, future investigations could consider salivary cortisol as reliable marker of the HPA-axis under psychosocial stress.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты