DOI 10.1097/00004424-199304000-00005
Sonographic image degradation after barium enema.
Аннотация
RATIONALE AND
OBJECTIVES
The authors previously showed that barium does not interfere with abdominal sonography performed after a biphasic upper gastrointestinal tract examination. This study was designed to assess the impact of a barium enema (BE) examination on the quality of abdominal sonography performed immediately after the barium enema.
METHODS
Forty patients scheduled for routine barium enemas (22 air contrast and 18 solid column) were prospectively examined with abdominal sonography before and after their BEs. The resulting 80 sonograms were randomized; three radiologists blindly assessed the quality of images of each of six anatomic areas (aorta, pancreas, porta hepatis, gallbladder, and the right and left lobes of the liver).
RESULTS
There was no statistically significant degradation of the images for the right and left lobes of the liver and the pancreas. However, the images for the gallbladder, porta hepatis, and aorta had a statistically significant (P < .05) degradation of their ultrasound quality following barium enema.
CONCLUSIONS
Unlike upper gastrointestinal tract examination, BE examination does interfere with the quality of a subsequent abdominal ultrasonography. Thus, when both studies are required, sonography should be performed first.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.