m+Medelevator.RU
← Поиск публикаций
World journal of surgery · 2019

18F-Fluorocholine PET/CT and Parathyroid 4D Computed Tomography for Primary Hyperparathyroidism: The Challenge of Reoperative Patients.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Amadou Coralie, Bera Géraldine, Ezziane Malek, Chami Linda, Delbot Thierry, Rouxel Agnès, Leban Monique, Herve Genevieve, Menegaux Fabrice, Leenhardt Laurence, Kas Aurélie, Trésallet Christophe, Ghander Cécile, Lussey-Lepoutre Charlotte

Аннотация

BACKGROUND: To evaluate FCH-PET/CT and parathyroid 4D-CT so as to guide surgery in patients with primary hyperparathyroidism (pHPT) and prior neck surgery.

METHODS: Medical records of all patients referred for a FCH-PET/CT in our institution were systematically reviewed. Only patients with pHPT, a history of neck surgery (for pHPT or another reason) and an indication of reoperation were included. All patients had parathyroid ultrasound (US) and Tc-99m-sestaMIBI scintigraphy, and furthermore, some patients had 4D-CT. Gold standard was defined by pathological findings and/or US-guided fine-needle aspiration with PTH level measurement in the washing liquid.

RESULTS: Twenty-nine patients were included in this retrospective study. FCH-PET/CT identified 34 abnormal foci including 19 ectopic localizations. 4D-CT, performed in 20 patients, detected 11 abnormal glands at first reading and 6 more under FCH-PET/CT guidance. US and Tc-99m-sestaMIBI found concordant foci in 8/29 patients. Gold standard was obtained for 32 abnormal FCH-PET/CT foci in 27 patients. On a per-lesion analysis, sensitivity, specificity, positive and negative predictive values were, respectively, 96%, 13%, 77% and 50% for FCH-PET/CT, 75%, 40%, 80% and 33% for 4D-CT. On a per-patient analysis, sensitivity was 85% for FCH-PET/CT and 63% for 4D-CT. FCH-PET/CT results made it possible to successfully remove an abnormal gland in 21 patients, including 12 with a negative or discordant US/Tc-99m-sestaMIBI scintigraphy result, with a global cure rate of 73%.

CONCLUSION: FCH-PET/CT is a promising tool in the challenging population of reoperative patients with pHPT. Parathyroid 4D-CT appears as a confirmatory imaging modality.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты