Treatment of visual problems after intracorneal ring implantation.

Yildirim Aydin, Uslu Hasim, Kara Necip, Ozgurhan Engin Bilge

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report the effect of wavefront-guided photorefractive keratectomy and corneal collagen cross-linking (CXL) on visual problems after Ferrara ring segment placement.

MATERIALS AND

METHODS

A 32-year-old male patient was treated with a Ferrara ring segment for keratoconus. One year later, the ring was removed due to severe glare complaints. After 6 months, wavefront-guided photorefractive keratectomy and CXL were applied simultaneously to correct high order aberration and refractive error.

RESULTS

Six months after the wavefront-guided photorefractive keratectomy and CXL, the uncorrected distance visual acuity was 20/25, and there was a 30% decrease in coma aberrations. The glare complaint regressed.

CONCLUSION

Wavefront-guided surface ablation and CXL may reduce high order aberrations and glare complaints after intrastromal corneal ring implantation.

Для цитирования: Yildirim Aydin, Uslu Hasim, Kara Necip, Ozgurhan Engin Bilge. Treatment of visual problems after intracorneal ring implantation.. Clinical ophthalmology (Auckland, N.Z.). 2013. DOI: 10.2147/opth.s45773.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.