MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2013.03.022

Медицинская библиотека · Journal of cataract and refractive surgery · 2013

Efficacy of single or paired intrastromal corneal ring segment implantation combined with collagen crosslinking in keratoconus.

Yeung Sonia N, Ku Judy Y F, Lichtinger Alejandro, Low Stephanie A W, Kim Peter, Rootman David S

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the efficacy of single or paired intrastromal corneal ring segments (ICRS) combined with ultraviolet-A and riboflavin collagen crosslinking (CXL) in patients with keratoconus.

SETTING

Cornea Unit, Toronto Western Hospital, Toronto, Ontario, Canada.

DESIGN

Retrospective comparative case series.

METHODS

Consecutive patients with keratoconus had femtosecond laser-assisted ICRS implantation combined with same-day CXL between 2008 and 2011. The main outcome measures included improvement in visual acuity, subjective refractive error, keratometry values, and total higher-order aberration (HOA).

RESULTS

Eighty-five eyes of 74 patients with keratoconus (paired ICRS: 47 eyes of 40 patients; single ICRS: 38 eyes of 34 patients) were included in the study. The uncorrected distance visual acuity was significantly improved after single ICRS (3.4 lines; P=.04) and paired ICRS (2.7 lines; P=.01) implantation combined with CXL, while corrected distance visual acuity (CDVA) remained stable. The single and paired ICRS groups had a significant reduction in mean cylinder at 1 year (single ICRS: -3.84 diopters [D] ± 1.72 [SD] versus -2.19 ± 1.54 D, P=.02; paired ICRS: -3.91 ± 1.45 D versus -2.96 ± 1.92 D) (P=.02). There was no significant difference in total HOAs. Single ICRS implantation and paired ICRS implantation with CXL were equivalent in all refractive parameters. No patient lost lines of CDVA.

CONCLUSION

As determined by corneal topography, implantation of single or paired ICRS combined with same-day CXL was safe and effective in patients with keratoconus.

Для цитирования: Yeung Sonia N, Ku Judy Y F, Lichtinger Alejandro, Low Stephanie A W, Kim Peter, Rootman David S. Efficacy of single or paired intrastromal corneal ring segment implantation combined with collagen crosslinking in keratoconus.. Journal of cataract and refractive surgery. 2013. DOI: 10.1016/j.jcrs.2013.03.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.