MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0b013e318295b4f4

Медицинская библиотека · Eye & contact lens · 2013

An assessment of the optimal lens fit rate in keratoconus subjects using three-point-touch and apical touch fitting approaches with the rose K2 lens.

Romero-Jiménez Miguel, Santodomingo-Rubido Jacinto, González-Méijome Jose Manuel

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare the number of ordered lenses required to achieve an optimal lens fit between three-point-touch and apical touch fittings in keratoconus subjects with nipple and oval cones using the first definite apical clearance lens (FDACL) as a starting point.

METHODS

First trial lens was selected following manufacturer's guidelines and the back optic zone radius (BOZR) was flattened or steepened in 0.10 mm steps until a FDACL was found. Subsequently, subjects were randomly allocated to three-point-touch (BOZR 0.10 mm flatter than FDACL) and apical touch fittings (BOZR 0.40 mm flatter than FDACL). Changes were made solely in total lens diameter, edge lift, and/or back vertex power until an optimal lens fit was achieved. Differences between fitting approaches were compared in terms of optimal lens fit rates defined as the percentage of subjects successfully fitted with the first lens ordered from the manufacturer.

RESULTS

Sixty-one subjects (109 eyes) were randomly allocated to three-point-touch and apical touch fitting approaches. An average of 2.3 trial lenses were necessary to achieve the FDACL. An optimal lens fit rate was achieved with the first lens in 84 of 109 eyes (77%). No statistically significant differences in optimal lens fit rates were found between three-point-touch and apical touch fitting approaches (83% and 71%, respectively; P = 0.12) and between nipple and oval cones (81% and 68%, respectively; P = 0.12).

CONCLUSIONS

The use of the FDACL provides a systematic, reliable, and repeatable starting point for Rose K2 contact lens fitting in keratoconus. Eye care practitioners should anticipate higher optimal lens fit rates when using three-point-touch (83%) in comparison with apical touch contact lens fittings (71%).

Для цитирования: Romero-Jiménez Miguel, Santodomingo-Rubido Jacinto, González-Méijome Jose Manuel. An assessment of the optimal lens fit rate in keratoconus subjects using three-point-touch and apical touch fitting approaches with the rose K2 lens.. Eye & contact lens. 2013. DOI: 10.1097/icl.0b013e318295b4f4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.