MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0301-4738.109519

Медицинская библиотека · Indian journal of ophthalmology · 2013

Evaluation of intrastromal corneal ring segments for treatment of keratoconus with a mechanical implantation technique.

Tunc Zeki, Helvacioglu Firat, Sencan Sadik

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation in patients with keratoconus using a mechanical implantation technique.

MATERIALS AND

METHODS

Thirty eyes of 17 patients with keratoconus were enrolled. ICRSs (Keraring) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3-, 6-, and 12-month follow-ups were completed, and statistical analysis was performed.

RESULTS

The mean preoperative UDVA for all eyes was 1.36 ± 0.64 logMAR. At 12 months, the mean UDVA was 0.51 ± 0.28 logMAR (P = 0.001), and the mean preoperative CDVA was 0.57 ± 0.29 logMAR, which improved to 0.23 ± 0.18 (P = 0.001) at 1 year. There was a significant reduction in spherical equivalent refractive error from -6.42 ± 4.69 diopters (D) preoperatively to -1.26 ± 1.45 D (P = 0.001) at 1 year. In the same period, the mean K-readings improved from 49.38 ± 3.72 D to 44.43 ± 3.13 D (P = 0.001), and the mean ISAI improved from 7.92 ± 3.12 to 4.21 ± 1.96 (P = 0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during and or after surgery.

CONCLUSION

ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for keratoconus. All parameters improved by the 1-year follow-up.

Для цитирования: Tunc Zeki, Helvacioglu Firat, Sencan Sadik. Evaluation of intrastromal corneal ring segments for treatment of keratoconus with a mechanical implantation technique.. Indian journal of ophthalmology. 2013. DOI: 10.4103/0301-4738.109519.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.