MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2012.11.015

Медицинская библиотека · American journal of ophthalmology · 2013

Continuous corneal intrastromal ring implantation for treatment of keratoconus in an Iranian population.

Jabbarvand Mahmoud, Salamatrad Ahmad, Hashemian Hesam, Khodaparast Mehdi

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effect of mechanical implantation of a continuous intrastromal ring in keratoconus.

DESIGN

Prospective, interventional, nonrandomized, case series.

METHODS

The MyoRing (Dioptex GmbH) was implanted after creation of an intrastromal pocket for 95 eyes of 95 patients with moderate and advanced keratoconus. All patients had at least 12 months of follow-up. Preoperative and postoperative visual acuity, keratometry, aberrometry, and refraction were the main outcome measures of the study.

RESULTS

A significant improvement in uncorrected and corrected distance visual acuity was observed 1 month after surgery, which was consistent with the significant reduction in sphere (5.74 diopters [D]) and cylinder (3.02 D). No significant changes were detected in these parameters afterward. Furthermore, a significant corneal flattening of a mean value of 9.78 D was found. Both spherical myopia and astigmatism underwent reduction, but the reduction in myopia was more remarkable than astigmatism. Higher-order aberrations and coma-like aberrations decreased significantly, but spherical aberrations increased after surgery. No significant change in central corneal thickness was observed at any point after operation. There were no significant differences between 2 keratometry groups (higher or lower than 53 D) in visual gain after the procedure. There were no major complications during or after surgery. MyoRing explantation was performed in 4 eyes (4%). The refraction, visual acuity, and corneal topography returned to the preoperative status 1 month later for all 4 eyes.

CONCLUSIONS

MyoRing implantation has an acceptable efficacy profile in moderate and advanced keratoconus.

Для цитирования: Jabbarvand Mahmoud, Salamatrad Ahmad, Hashemian Hesam, Khodaparast Mehdi. Continuous corneal intrastromal ring implantation for treatment of keratoconus in an Iranian population.. American journal of ophthalmology. 2013. DOI: 10.1016/j.ajo.2012.11.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.