m+Medelevator.RU
← Поиск публикаций
Investigative ophthalmology & visual science · 2013

Finite-element modeling of intrastromal ring segment implantation into a hyperelastic cornea.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kling Sabine, Marcos Susana

Аннотация

PURPOSE: Intrastromal corneal-ring segments (ICRSs) are applied to improve highly distorted vision in keratoconic, myopic, and astigmatic patients. Selections of ICRS geometry and position are primarily based on empirical nomograms. We developed a finite-element model (FEM) predicting the corneal response to different ICRS geometries in normal and keratoconic corneas.

METHODS: A two-dimensional FEM was built in proprietary software (ANSYS-APDL), consisting of hyperelastic ocular tissues (cornea, limbus, sclera) and a triangular/hexagonal ICRS of poly(methyl methacrylate). An incrustation model was developed considering the local material addition and rigidity increase at the ICRS position and also for the triangular ICRS the geometric difference between its base (plane) and corneal tunnel (parallel to corneal surface). Different ICRS heights (150-350 μm) and optical zones (4.4-6.6 mm) were simulated. An axis-symmetric model of keratoconus was studied, where corneal elasticity was decreased locally.

RESULTS: ICRS GEOMETRY (HEIGHT AND OPTICAL ZONE) HAD A SIGNIFICANT INFLUENCE ON CORNEAL POWER: changes from 4.08 to -17.7 diopters (D) (healthy)/3.31 to -20.5 D (keratoconic) were observed. Central corneal thickness was predicted to increase by up to 38.5 μm (healthy)/97.9 μm (keratoconic). Spherical aberration also changed upon ICRS implantation. The protrusion of the posterior cornea behind the rings was well predicted. The model confirmed the clinically reported trends on the effect of ring geometry.

CONCLUSIONS: FEM is a powerful tool to study the corneal response to ICRS implantation. The combination of FEM with individual biomechanical properties and geometry of patients holds promise to increase the predictability of ICRS surgery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты