Journal of cataract and refractive surgery · 2012
Changes in visual function under mesopic and photopic conditions after intrastromal corneal ring segment implantation for different stages of keratoconus.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Carballo Jesús, Puell María Cinta, Cuiña Ricardo, Vázquez José María, Benitez-del-Castillo José M
Аннотация
PURPOSE: To analyze and compare the changes in visual function under mesopic and photopic conditions in different stages of keratoconus before and after Keraring intrastromal corneal ring segment (ICRS) implantation.
SETTING: Clinico San Carlos Hospital and Faculty of Optics and Optometry, Complutense University, Madrid, Spain.
DESIGN: Case series.
METHODS: Keratoconic eyes were evaluated under mesopic (0.1 to 0.2 candelas [cd]/m(2)) and photopic (85 cd/m(2)) conditions. LogMAR high-contrast corrected distance visual acuity (CDVA) and low-contrast CDVA were assessed using the Bailey-Lovie test and logarithmic contrast sensitivity, using the Pelli-Robson test.
RESULTS: The study evaluated 12 eyes with stage I keratoconus, 21 eyes with stage 2, and 14 eyes with stage 3. The mean change in photopic high-contrast CDVA was 0.16 logMAR ± 0.20 (SD) (P<.00001). Photopic low-contrast CDVA increased by a mean of 0.14 ± 0.26 logMAR (P=.0005), photopic contrast sensitivity by a mean of 0.09 ± 0.22 logMAR (P=.005), and mesopic high-contrast CDVA by a mean of 0.10 ± 0.26 logMAR (P=.03). There were no significant differences between stages. Surgery did not affect the mean changes in mesopic low-contrast CDVA or mesopic contrast sensitivity for any stage.
CONCLUSIONS: Implantation of ICRS in keratoconic eyes increased photopic high-contrast CDVA, low-contrast CDVA, and contrast sensitivity. Under low luminance, the mean changes in high-contrast CDVA, low-contrast CDVA, and contrast sensitivity did not worsen after ICRS implantation performed 5.0 mm from the visual axis, despite the rings being partially superimposed on the mydriatic pupil.
SETTING: Clinico San Carlos Hospital and Faculty of Optics and Optometry, Complutense University, Madrid, Spain.
DESIGN: Case series.
METHODS: Keratoconic eyes were evaluated under mesopic (0.1 to 0.2 candelas [cd]/m(2)) and photopic (85 cd/m(2)) conditions. LogMAR high-contrast corrected distance visual acuity (CDVA) and low-contrast CDVA were assessed using the Bailey-Lovie test and logarithmic contrast sensitivity, using the Pelli-Robson test.
RESULTS: The study evaluated 12 eyes with stage I keratoconus, 21 eyes with stage 2, and 14 eyes with stage 3. The mean change in photopic high-contrast CDVA was 0.16 logMAR ± 0.20 (SD) (P<.00001). Photopic low-contrast CDVA increased by a mean of 0.14 ± 0.26 logMAR (P=.0005), photopic contrast sensitivity by a mean of 0.09 ± 0.22 logMAR (P=.005), and mesopic high-contrast CDVA by a mean of 0.10 ± 0.26 logMAR (P=.03). There were no significant differences between stages. Surgery did not affect the mean changes in mesopic low-contrast CDVA or mesopic contrast sensitivity for any stage.
CONCLUSIONS: Implantation of ICRS in keratoconic eyes increased photopic high-contrast CDVA, low-contrast CDVA, and contrast sensitivity. Under low luminance, the mean changes in high-contrast CDVA, low-contrast CDVA, and contrast sensitivity did not worsen after ICRS implantation performed 5.0 mm from the visual axis, despite the rings being partially superimposed on the mydriatic pupil.