m+Medelevator.RU
← Поиск публикаций
Journal of the American Heart Association · 2023

Splanchnic Nerve Modulation Effects on Surrogate Measures of Venous Capacitance.

Клиническое исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kittipibul Veraprapas, Ganesh Arun, Coburn Aubrie, Coyne Brian J, Gray James Matthew, Molinger Jeroen, Ray Neil, Podgoreanu Mihai, McCartney Sharon L, Mamoun Negmeldeen, Fitzhugh Robert Curtis, Lurz Philipp, Green Cynthia L, Hernandez Adrian F, Patel Manesh R, Fudim Marat

Аннотация

Background Splanchnic nerve modulation (SNM) is an emerging procedure to reduce cardiac filling pressures in heart failure. Although the main contributor to reduction in cardiac preload is thought to be increased venous capacitance in the splanchnic circulation, supporting evidence is limited. We examined changes in venous capacitance surrogates pre- and post-SNM. Methods and Results This is a prespecified analysis of a prospective, open-label, single-arm interventional study evaluating the effects of percutaneous SNM with ropivacaine in chronic heart failure with elevated filling pressures at rest and with exercise. Patients underwent cardiopulmonary exercise testing with invasive hemodynamic assessment pre- and post-SNM. Blood pressure changes with modified Valsalva maneuver and hemoconcentration, pre- and post-SNM were compared using a repeated measures model. Inferior vena cava diameter and collapsibility (>50% decrease in size with inspiration), and presence of bendopnea pre- and post-SNM were also compared. Fifteen patients undergoing SNM (age 58 years, 47% women, 93% with left ventricular ejection fraction ≤35%) were included. After SNM, changes in systolic blood pressure during Valsalva (peak-to-trough) were greater (41 versus 48 mm Hg, P=0.025). Exercise-induced hemoconcentration was unchanged (0.63 versus 0.43 g/dL, P=0.115). Inferior vena cava diameter was reduced (1.59 versus 1.30 cm, P=0.034) with higher collapsibility (33% versus 73%, P=0.014). Bendopnea was less (47% versus 13%, P=0.025). Conclusions SNM resulted in increased venous capacitance, associated decreased cardiac preload, and decreased bendopnea. Minimally invasive measures of venous capacitance could serve as markers of successful SNM. Long-term effects of SNM on venous capacitance warrant further investigation for heart failure management. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT03453151.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты