Assessing muscle compliance in stroke with the Myotonometer.
Аннотация
BACKGROUND
This study explores changes of the intrinsic biomechanical property in the biceps brachii muscle after a hemispheric stroke using the Myotonometry technique.
METHODS
Nineteen subjects with chronic hemiplegia participated in the study. Myotonometer was used to measure tissue displacement when compression force was applied at 8 levels from 2.45N to 19.6N. Muscle displacement and compliance were determined and averaged over multiple trials.
FINDINGS: Statistical analysis indicated a significant decrease in muscle displacement and compliance in the spastic muscles compared with the contralateral side (muscle displacements: spastic: 4.51 (0.31) mm, contralateral: 5.74 (0.37) mm, p<0.005; compliance: spastic: 0.17 (0.011) mm/N, contralateral: 0.22 (0.014) mm/N, p<0.005). Correlation analysis, however, did not show any association between clinical assessments and myotonometric measurement (p>0.1).
INTERPRETATION: Alterations of muscle compliance in the spastic side reflect changes in the contractile or intrinsic mechanical properties after a stroke. Findings of the study have demonstrated high sensitivity and effectiveness of the Myotonometer in assessing muscle compliance changes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.