OBJECTIVE

Patients undergoing multiple valve surgery represent a high-risk group who could potentially benefit from a reduction of cross-clamp and cardiopulmonary bypass times because prolonged bypass and cross-clamp times are considered independent risk factors for increased morbidity and mortality after cardiac surgery.

METHODS

Between July 2013 and November 2014, 16 patients underwent rapid deployment aortic valve replacement with the EDWARDS INTUITY valve system in the setting of concomitant mitral disease. Fifteen patients showed mitral regurgitation, whereas one patient had severe mitral stenosis. Fourteen patients received mitral valve repair and two patients received biological mitral valve replacement. Tricuspid valve repair was performed additionally in two patients. The mean ± SD age was 72.8 ± 8.4 years, and the mean ± SD logistic EuroSCORE II is 8.7% ± 3.4%.

RESULTS

Within a 30-day perioperative period, no patient was lost (n = 0). The mean ± SD follow-up time was 11 ± 2 months. At 1 year, the overall survival was 81% (n = 13). A mean ± SD transaortic gradient of 10.7 ± 2.3 mm Hg and a mean ± SD effective orifice area of 1.7 ± 0.3 cm were measured echocardiographically. No higher-grade paravalvular leak (aortic insufficiency > 1+) occurred. Eight patients (61%) had no residual mitral regurgitation, four patients (30%) showed trivial regurgitation (1/4), and one patient (7.3%) had moderate mitral regurgitation (2/4). No interference of the subannular stent frame with the reconstructed valve or the biological mitral prosthesis was seen.

CONCLUSIONS

Rapid deployment aortic valve replacement with the EDWARDS INTUITY valve system in combined aortic and mitral valve surgery can be performed safely with reproducible results. One-year follow-up data of this small series shows encouraging results potentially justifying the extension of the indication for rapid deployment valves to patients with concomitant mitral disease. Especially elderly patients undergoing multiple valve surgery may benefit from a reduction of cardiopulmonary bypass and myocardial ischemic times.

Для цитирования: Schlömicher Markus, Bechtel Matthias, Taghiyev Zulfugar, Al-Jabery Yazan, Haldenwang Peter Lukas, Moustafine Vadim, Strauch Justus Thomas. The Use of Rapid Deployment Valves in Combined Aortic and Mitral Valve Surgery: One-Year Clinical and Echocardiographic Outcomes.. Innovations (Philadelphia, Pa.). 2017. DOI: 10.1097/imi.0000000000000373.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.