m+Medelevator.RU
← Поиск публикаций
Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2011

Accuracy of retinopathy of prematurity image-based diagnosis by pediatric ophthalmology fellows: implications for training.

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Myung Jane S, Paul Chan Robison Vernon, Espiritu Michael J, Williams Steven L, Granet David B, Lee Thomas C, Weissgold David J, Chiang Michael F

Аннотация

PURPOSE: To measure the accuracy of image-based retinopathy of prematurity (ROP) diagnosis by pediatric ophthalmology fellows.

METHODS: This was a comparative case series of expert versus nonexpert clinicians in image-based ROP diagnosis. An atlas of 804 retinal images was captured from 248 eyes of 67 premature infants with a wide-angle camera (RetCam-II, Clarity Medical Systems, Pleasanton, CA). Images were uploaded to a study website from which an expert pediatric retinal specialist and five pediatric ophthalmology fellows independently provided a diagnosis (no ROP, mild ROP, type 2 ROP, or treatment-requiring ROP) for each eye. Two different retinal specialists experienced in ROP examination served as additional controls. Primary outcome measures were sensitivity and specificity of image-based ROP diagnosis by fellows compared to a reference standard of image-based interpretation by the expert pediatric retinal specialist. Secondary outcome measure was intraphysician reliability.

RESULTS: For detection of mild or worse ROP, the mean (range) sensitivity among the five fellows was 0.850 (0.670-0.962) and specificity was 0.919 (0.832-0.964). For detection of type 2 or worse ROP by fellows, mean (range) sensitivity was 0.527 (0.356-0.709) and specificity was 0.938 (0.777-1.000). For detection of treatment-requiring ROP, mean (range) sensitivity was 0.515 (0.267-0.765) and specificity was 0.949 (0.805-1.00).

CONCLUSIONS: Pediatric ophthalmology fellows in this study demonstrated high diagnostic specificity in image-based ROP diagnosis; however, sensitivity was lower, particularly for clinically significant disease.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты