Maintaining optimal oxygen saturation in premature infants.

Lau Yoke Yen, Tay Yih Yann, Shah Varsha Atul, Chang Pisun, Loh Khuan Tai

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Advances in technology have resulted in increasing survival rates for premature infants. Oxygen therapy is commonly used in neonatal units as part of respiratory support. The number of premature infants in our institution surviving with severe (stage ≥3) retinopathy of prematurity (ROP) prompted a review of oxygen therapy as a contributing factor. Prolonged exposure to high concentrations of oxygen may cause irreversible damage to the eyes of very-low-birth-weight preterm infants and is a potential cause of blindness.

OBJECTIVE

We developed strategies to reduce incidence of severe ROP requiring laser surgery in premature infants.

METHODS

We studied 37 preterm infants who were born at a gestational age of <32 weeks, with a birth weight of <1500 g, receiving supplemental oxygen, and had been admitted to our neonatal intensive care unit. Infants received oxygen via mechanical ventilator, nasal continuous positive airway pressure (CPAP), or intranasal (I/N) and titration of oxygen was based on each infant's measured oxygen saturation (Spo(2)). For each infant, we monitored the Spo(2) trend, Spo(2) alarm limit, and the percentage of time that the alarm limit was set incorrectly. We implemented a Spo(2) targeting protocol and developed an algorithm for titrating fraction of inspired oxygen (Fio(2)).

RESULTS

After phase 1 of implementation, the percentage of time that Spo(2) readings were >95% was reduced to between 20% and 50%. However, our findings raised concern regarding the wide fluctuation of Spo(2) readings because of inconsistency in Fio(2) titration, which can contribute to deviation from the optimal target range. Accordingly, we developed an algorithm for titrating Fio(2) aimed at maintaining each infant's Spo(2) within the optimal target range. After phase 2 of implementation, the percentage of Spo(2) readings >95% was markedly reduced to between 0% and 15%. The incidence of infants with severe ROP requiring laser surgery decreased from 5 to 1.

CONCLUSIONS

A change in clinical practice aimed at maintaining oxygen within the target range to avoid a high Spo(2) was associated with a significant decrease in the incidence of both severe ROP and the need for laser surgery, thus reducing hospital costs and length of hospital stays for premature infants.

Для цитирования: Lau Yoke Yen, Tay Yih Yann, Shah Varsha Atul, Chang Pisun, Loh Khuan Tai. Maintaining optimal oxygen saturation in premature infants.. The Permanente journal. 2011. DOI: 10.7812/tpp/11.998.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.