m+Medelevator.RU
← Поиск публикаций
Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2011

Combining ROPtool measurements of vascular tortuosity and width to quantify plus disease in retinopathy of prematurity.

СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cabrera Michelle T, Freedman Sharon F, Kiely Amanda E, Chiang Michael F, Wallace David K

Аннотация

BACKGROUND: ROPtool is a computer program that is used to measure retinal vascular tortuosity and width. Our aim was to determine the best method for combining ROPtool's tortuosity and width values into an overall measure of plus disease.

METHODS: ROPtool was used to measure vessel tortuosity and width in 184 quadrants of 46 RetCam images of premature infants. Five methods for combining tortuosity and width were assessed: the plus index and sum of adjusted indices provide tortuosity and width values using different scales; tortuosity-weighted plus increases the contribution of width as tortuosity increases; the vessel area index is used to average vessel area per unit length; and regression analysis establishes a mathematical equation to fit expert diagnosis. For each method, receiver operating characteristic curves were generated with a 3-expert consensus as the reference standard. Optimal cut points for plus disease were selected and then tested on a second set of 184 quadrants of 46 different images.

RESULTS: When applied to the second data set, areas under the receiver operating characteristic curves were 0.857 for plus index, 0.918 for sum of adjusted indices, 0.941 for tortuosity-weighted plus, 0.868 for vessel area index, and 0.934 for regression analysis methods. The highest sensitivities and specificities were for tortuosity-weighted plus (85% for both) and regression analysis methods (85% and 86%, respectively).

CONCLUSIONS: When combining ROPtool's measures of width and tortuosity, sum of adjusted indices, tortuosity-weighted plus, and regression analysis methods had high overall accuracy. ROPtool can now generate a clinically meaningful quantitative description of vascular abnormality to aid in plus disease diagnosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты