MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Respiratory care · 2005

Delivered oxygen concentrations using low-flow and high-flow nasal cannulas.

Wettstein Richard B, Shelledy David C, Peters Jay I

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Nasal cannulas are commonly used to deliver oxygen in acute and chronic care settings; however, there are few data available on delivered fraction of inspired oxygen (F(IO(2))). The purposes of this study were to determine the delivered F(IO(2)) on human subjects using low-flow and high-flow nasal cannulas, and to determine the effects of mouth-closed and mouth-open breathing on F(IO(2)).

METHODS

We measured the pharyngeal F(IO(2)) delivered by adult nasal cannulas at 1-6 L/min and high-flow nasal cannulas at 6-15 L/min consecutively in 10 normal subjects. Oxygen was initiated at 1 L/min, with the subject at rest, followed by a period of rapid breathing. Gas samples were aspirated from a nasal catheter positioned with the tip behind the uvula. This process was repeated at each liter flow. Mean, standard deviation, and range were calculated at each liter flow. F(IO(2)) during mouth-open and mouth-closed breathing were compared using the dependent test for paired values, to determine if there were significant differences.

RESULTS

The mean resting F(IO(2)) ranged from 0.26-0.54 at 1-6 L/min to 0.54-0.75 at 6-15 L/min. During rapid breathing the mean F(IO(2)) ranged from 0.24-0.45 at 1-6 L/min to 0.49-0.72 at 6-15 L/min. The mean F(IO(2)) increased with increasing flow rates. The standard deviation (+/- 0.04-0.15) and range were large, and F(IO(2)) varied widely within and between subjects. F(IO(2)) during mouth-open breathing was significantly (p < 0.05) greater than that during mouth-closed breathing.

CONCLUSIONS

F(IO(2)) increased with increasing flow. Subjects who breathed with their mouths open attained a significantly higher F(IO(2)), compared to those who breathed with their mouths closed.

Для цитирования: Wettstein Richard B, Shelledy David C, Peters Jay I. Delivered oxygen concentrations using low-flow and high-flow nasal cannulas.. Respiratory care. 2005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.