MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-025-11851-3

Медицинская библиотека · European radiology · 2025

Dual-energy CT liver fat fraction as prognostic imaging biomarker in critically ill patients.

Erley Jennifer, Breckow Julia, Roedl Kevin, Ozga Ann-Kathrin, Duoerkongjiang Alidan, de Heer Geraldine, Schubert Niklas, Pallasch Fabian, Burdelski Christoph, Kluge Stefan, Yamamura Jin, Adam Gerhard, Molwitz Isabel

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To analyze changes in the liver dual-energy CT fat fraction (liver DECT FF) at the intensive care unit (ICU), and its prognostic value.

MATERIALS AND

METHODS

Intubated ICU patients were retrospectively included, who received two clinical DECT (CT1 and CT2) within a minimum interval of 10 days between 11/2019 and 12/2022. The liver DECT FF was determined by combining two regions of interest (ROI) in the right and one ROI in the left liver lobe (minimum area 3.6 cm2). The skeletal muscle index, muscle radiodensity attenuation, subcutaneous/visceral adipose tissue area, and waist circumference were assessed. Pre-existing diseases, reasons for ICU admission, ICU scoring systems, and in-hospital mortality were noted. t-tests, Wilcoxon tests, linear or Cox regression, Pearson correlation, and intraclass correlation coefficients (ICC) were employed.

RESULTS

Of 76 total patients, 43.4% were female (age 61 ± 12 years) and 97.4% received parenteral nutrition. In-hospital mortality was 60.8%. The liver DECT FF at CT1 was the only parameter associated with in-hospital mortality (hazard ratio: 1.15 [95% confidence interval: 1.07-1.24], p < 0.001), and a shorter ICU stay (-3.66 [-6.29 to -1.02] days, p < 0.007). DECT FF was not associated with ICU scoring systems. It did not relevantly change within a median of 8 days (3.3 ± 5.5% at CT1; 2.7 ± 4.3% at CT2, p = 0.315). Subset inter-observer reproducibility was good (ICC: 0.87 [0.66-0.95]).

CONCLUSION

The liver DECT FF may serve as an independent prognostic imaging biomarker of mortality in critically ill patients, with a superior value to single-energy body composition parameters.

KEY POINTS: Question Although the risk of liver steatosis is increased in critically ill patients, it is unknown if liver fat content, when quantified using DECT, is of prognostic value. Findings The liver DECT FF is associated with in-hospital mortality in critically ill patients. Clinical relevance The liver DECT FF may be superior for survival prognosis than single-energy CT body composition parameters of muscle and fat tissue at the ICU.

Для цитирования: Erley Jennifer, Breckow Julia, Roedl Kevin, Ozga Ann-Kathrin, Duoerkongjiang Alidan, de Heer Geraldine, Schubert Niklas, Pallasch Fabian, Burdelski Christoph, Kluge Stefan, Yamamura Jin, Adam Gerhard, Molwitz Isabel. Dual-energy CT liver fat fraction as prognostic imaging biomarker in critically ill patients.. European radiology. 2025. DOI: 10.1007/s00330-025-11851-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.