MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2009.07.020

Медицинская библиотека · American journal of ophthalmology · 2009

Pulsar perimetry in the diagnosis of early glaucoma.

Zeppieri Marco, Brusini Paolo, Parisi Lucia, Johnson Chris A, Sampaolesi Roberto, Salvetat Maria Letizia

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the ability of Pulsar perimetry (Pulsar) in detecting early glaucomatous visual field (VF) damage in comparison with Frequency Doubling Technology (FDT), Scanning Laser Polarimetry (SLP, GDx VCC), and Heidelberg Retina Tomography (HRT).

DESIGN

Prospective observational cross-sectional case study.

METHODS

This multicenter study included: 87 ocular hypertensives (OHT); 67 glaucomatous optic neuropathy (GON) patients; 75 primary open-angle glaucoma (POAG) patients; and 90 normals. All patients underwent standard automated perimetry (SAP) HFA 30-2, Pulsar T30W, FDT N-30, HRT II, and GDx VCC. Area under Receiver Operating Characteristic Curves (AROCs) for discriminating between healthy and glaucomatous eyes and agreement among instruments were determined.

RESULTS

The best parameters for Pulsar, FDT, HRT, and GDx were, respectively: loss variance square root; no. of areas with P< 5%; Cup-Shape-Measure; and Nerve Fiber Indicator (NFI). In detecting POAG eyes, Pulsar (AROC, 0.90) appeared comparable with FDT (0.89) and significantly better than HRT (0.82) and GDx (0.79). For GON, Pulsar ability (0.74) was higher than GDx (0.69) and lower than FDT (0.80) and HRT (0.83). The agreement among instruments ranged from 0.12 to 0.56. Pulsar test duration was significantly shorter than SAP and FDT (P< .001).

CONCLUSIONS

Pulsar T30W test is a rapid and easy perimetric method, showing higher sensitivity than SAP in detecting early glaucomatous VF loss. Its diagnostic ability is good for detecting early perimetric POAG eyes and fair for GON eyes. Pulsar performance was comparable with FDT, HRT, and GDx, even if the agreement between instruments was poor to fair.

Для цитирования: Zeppieri Marco, Brusini Paolo, Parisi Lucia, Johnson Chris A, Sampaolesi Roberto, Salvetat Maria Letizia. Pulsar perimetry in the diagnosis of early glaucoma.. American journal of ophthalmology. 2009. DOI: 10.1016/j.ajo.2009.07.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.