MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41551-023-01062-w

Медицинская библиотека · Nature biomedical engineering · 2023

Posterior scleral birefringence measured by triple-input polarization-sensitive imaging as a biomarker of myopia progression.

Liu Xinyu, Jiang Liqin, Ke Mengyuan, Sigal Ian A, Chua Jacqueline, Hoang Quan V, Chia Audrey Wi, Najjar Raymond P, Tan Bingyao, Cheong Jocelyn, Bellemo Valentina, Chong Rachel S, Girard Michaël J A, Ang Marcus, Liu Mengyang, Garhöfer Gerhard, Barathi Veluchamy A, Saw Seang-Mei, Villiger Martin, Schmetterer Leopold

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

In myopic eyes, pathological remodelling of collagen in the posterior sclera has mostly been observed ex vivo. Here we report the development of triple-input polarization-sensitive optical coherence tomography (OCT) for measuring posterior scleral birefringence. In guinea pigs and humans, the technique offers superior imaging sensitivities and accuracies than dual-input polarization-sensitive OCT. In 8-week-long studies with young guinea pigs, scleral birefringence was positively correlated with spherical equivalent refractive errors and predicted the onset of myopia. In a cross-sectional study involving adult individuals, scleral birefringence was associated with myopia status and negatively correlated with refractive errors. Triple-input polarization-sensitive OCT may help establish posterior scleral birefringence as a non-invasive biomarker for assessing the progression of myopia.

Для цитирования: Liu Xinyu, Jiang Liqin, Ke Mengyuan, Sigal Ian A, Chua Jacqueline, Hoang Quan V, Chia Audrey Wi, Najjar Raymond P, Tan Bingyao, Cheong Jocelyn, Bellemo Valentina, Chong Rachel S, Girard Michaël J A, Ang Marcus, Liu Mengyang, Garhöfer Gerhard, Barathi Veluchamy A, Saw Seang-Mei, Villiger Martin, Schmetterer Leopold. Posterior scleral birefringence measured by triple-input polarization-sensitive imaging as a biomarker of myopia progression.. Nature biomedical engineering. 2023. DOI: 10.1038/s41551-023-01062-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.